Helpful Hints
1. Fines are small pieces of broken pellets (sawdust). Fines do
not flow easily and often build up on the hopper funnel bottom
angles. These fines can be pushed into the feeder opening and
then fill the hopper with pellets. As the system works, they will
be burned.
2. The "TEST" cycle will operate the feeder motor for exactly one
minute. Turning to "TEST" again and again may feed too much
fuel into the burn pot causing excessive smoke on start-up.
3. The firebox low pressure switch will not allow the auger motor
or the igniter element to operate if the view door is open.
4. Adjust Feed Rate. If this is your first fire or you are trying different
pellets, set the feed adjuster to #4, Fig. 3. This is a conservative
number and will probably need to be increased. After you know
a feed rate setting that works well, use that setting. Remember,
if your feed rate is too high you may waste fuel.
5. This is usually a weekly maintenance procedure. Cleaning
the burn pot with the scraper with a small amount of new fuel in
the bottom is not a problem. First, scrape the ashes on the front
of the burn pot into the ash pan. Then scrape the holed surface
downward into the burn pot. When the stove is ignited these
scrapings will be pushed out by the feeder.
6. The ash pan can hold the ashes from approximately 1 ton of
premium fuel. This means the ashes will only need to be emptied
a few times a year.
7. Setting the feed adjuster # for maximum burn: With the unit
burning in "AUTO", turn to "Stove Mode" and put the fan on "H".
Set the Temperature Dial to #7. Allow the unit to burn for about
30 minutes and check ash on front of burn pot. Fig. 4. If the ash
line is larger than 1", turn the feed adjuster from #4 to #5. Allow
another 30 minutes of burn time and check again. If , at #6 setting,
a 1" or less ash bed is not obtainable, it is not a problem. The 1"
ash bed is only a maximum burn rate and at most normal settings
the ash bed will be larger.

Automatic Start up

See Hint #7.
1"
Fig. 4
Starting First Fire
Igniter Switch to "AuTO" (down position)
Make sure the unit is plugged into a 120 VAC, 60
HZ electrical source. The power light should be
the only light lit.
ImPOrTANT: To avoid unwanted smoke, Be sure
there is no fuel or other combustibles in the ash
pan prior to lighting.
Keep all doors closed during operation. Maintain
all seals and gaskets in good condition.
1. Turn mode Selector to "OFF".
2. Fill hopper with pellets.
3. Clean burn pot with scraper, if necessary.
4. If starting after an empty hopper, turn Feed
Adjuster to "TEST" (for one 60 second cycle).
This will feed pellets into the auger tube and also
allow you to check the motors for operation. NOTE:
The auger motor will not operate with the view
door or ash pan door open.
5. Turn Feed Adjuster to #4.
6. Flip the Igniter Switch down into the "AUTO"
position.
7. Turn the Temperature dial to the desired room
temperature.
8. Turn the mode Selector to Room Temperature
or Stove Temperature.
9. Fill the hopper with pellets and remove ashes
as required.
6
warning
NEvEr uSE gASOlINE, gASOlINE-TYPE lANTErN
FuEl, KErOSENE, ChArCOAl lIghTEr FluId,
Or SImIlAr lIQuIdS TO STArT Or 'FrEShEN uP'
A FIrE IN ThIS hEATEr. KEEP All SuCh lIQuIdS
wEll AwAY FrOm ThE hEATEr whIlE IN uSE.