3. ELECTRICAL ADJUSTMENT

3-1. Table for Servicing Tools
Ref. No.
Name
J-1
Color viewer 5,100 K
J-2
Siemens star chart
J-3
Calibration software
J-4
Extension cord
Note: J-1 color viewer is 100 - 110 VAC only.
J-2 Siemens star chart is the same as before models.
J-1
J-3
3-2. Equipment
1. Oscilloscope
2. Digital voltmeter
3. AC adaptor
4. IBM R -compatible PC
5. DC regulated power supply
3-3. Adjustment Items and Order
1. IC501 Frequency Adjustment
2. 5.0 V (D) Voltage Adjustment
3. 3.3 V (D) Voltage Adjustment
4. 12.4 V (L) Voltage Adjustment 1
5. 12.4 V (L) Voltage Adjustment 2
6. 5.8 V (L) Voltage Adjustment
7. CCD Defect Defect Adjustment
8. AWB Adjustment
9. Flange-back Adjustment
10. LCD Panel Adjustment
10-1. LCD H AFC Adjustment
10-2. LCD RGB Offset Adjustment
10-3. LCD Gain Adjustment
10-4. LCD Blue Brightness Adjustment
10-5. LCD Red Brightness Adjustment
Part code
VJ8-0007
VJ8-0166
VJ8-0151
J-2
J-4
3-4. Setup
1. System requirements
Windows 95 or 98
IBM R -compatible PC with 486 or higher processor
CD-ROM drive
3.5-inch high-density diskette drive
Serial port with standard RS-232C interface
8 MB RAM
Hard disk drive with at least 15 MB available
VGA or SVGA monitor with at least 256-color display
2. Installing calibration software
1. Insert the calibration software installation diskette into your
diskette drive.
2. Open the explorer.
3. Copy the DSC Cal folder on the floppy disk in the FD drive
to a folder on the hard disk.
3. Color Viewer
Turn on the switch and wait for 30 minutes for aging to take
place before using Color Pure.
4.Computer screen during adjustment
Calibration
Upload
AWB
Firmware
Focus
Image
UV Matrix
Initialize
LCD Type
Firmware Version:
LCD
R Bright
B Bright
VCOMDC
VCOMPP
RGB Offset
Gain
Tint
Phase
H AFC
Test

Hide quick links: