WARNING
ELECTRICAL SHOCK HAZARD
Disconnect power before servicing.
Replace all panels before operating.
Failure to do so could result in death or
electrical shock.
DUAL ELEMENT INFINITE
SWITCH (LF)
L2 - Red
L1 - Black
P1
4 - Or/Bk
Pushbutton
Inner Element
Refer to page 3-4 for the procedure for servic-
ing the dual element infinite switch.
1.
Disconnect the electrical power to the
range.
2.
Set the ohmmeter to the R X 1 scale.
3.
Turn the dual element infinite switch to the
"single" position.
P2
S2 - Blue
Pilot Light
4A - Or/Wh
Outer Element
2 - Violet
4.
Touch the ohmmeter test leads to the
following terminals. The meter should in-
dicate continuity (0 Ω):
a) P1 - 4.
b) P1 - S2.
c) P2 - 2.
5.
Touch the ohmmeter test leads to termi-
nals P1 and 4a. The meter should indicate
an open circuit (infinite).
L1
BK
P1
4
OR/BK
INNER ELEMENT
6.
Turn the dual element infinite switch to the
"dual" position.
7.
Touch the ohmmeter test leads to the
following terminals. The meter should in-
dicate continuity (0 Ω):
a) P1 - 4.
b) P1 - 4a.
c) P1 - S2.
d) P2 - 2.
L1
BK
P1
4
OR/BK
INNER ELEMENT
4-5
L2
R
P2
S2
PILOT LIGHT
BU
4A
OUTER ELEMENT
OR/WH
SINGLE
POSITION
2
VLT
PUSHBUTTON
L2
R
P2
S2
PILOT LIGHT
BU
4A
OUTER ELEMENT
OR/WH
DUAL
POSITION
2
VLT
PUSHBUTTON