Description Of Error Codes And Causes; Main Common - Electrolux W555H Service Manual

Type w.55.h
Hide thumbs Also See for W555H:
Table of Contents

Advertisement

Troubleshooting
56

13.3 Description of error codes and causes

MAIN COMMON

10:11 REAL TIME CLOCK OUT OF ORDER
The real time clock is used by the CPU, measuring time, power failure, error codes, etc.
The error code is activated if there is a time out in the communication with the internal real time
clock in the CPU or if the data sent to/from the real time clock is incorrect.
The error can only be removed by turning of the power to the machine for 30 seconds.
10:13 INITIALIZATION FAILED
The CPU has an internal time limit for initialization of the system.
The error code is activated if 15 seconds has expired during start up and the hardware still is not
initialized.
Press the control knob/start button to retry.