Viewfinder Basic Menu
Basic menu page 2
mA.IRIS:±0
DTL LEV: ±0
M.BLACK:±0
STRETCH:±0
SHUTTER:OFF
Item
Settings
A. IRIS
–1.0, –0.5, ±0 (normal value), +0.5,
Sets a base value
+1.0
for auto adjustment
Negative adjustment values set a
of lens iris.
narrower lens iris and positive values
set a wider lens iris.
DTL LEV
–99 to ±0 (normal value) to +99
Sets the detail
Negative adjustment values soften the
(edge) emphasis.
image's edges and positive values
sharpen them.
M. BLACK
–99 to ±0 (normal value) to +99
Sets the master
Negative adjustment values make
pedestal level.
dark areas of the picture darker and
increase the contrast. Positive
adjustment values dark areas of the
picture lighter and reduce the
contrast.
STRETCH
–16 to ±0 (normal value) to +15
Sets black stretch/
This function adjusts the intensity of
compress value.
dark areas of the screen. Negative
values make these areas darker
(black compress) and positive values
make these areas brighter (black
stretch).
SHUTTER
DXC-D30: 1/100 (normal value),
Sets shutter speed
1/250, 1/500, 1/1000, 1/2000,
or CLS/EVS setting
EVS, CLS (60.4 Hz to 200.3 Hz)
(see page 75) .
DXC-D30P: 1/60 (normal value), 1/
250, 1/500, 1/1000, 1/2000, EVS,
CLS (50.3 Hz to 201.4 Hz)
This selects either the shutter speed
or the scan frequency or EVS for the
clear scan function.
52
Chapter 4 Viewfinder Screen Indications and Menus
Basic menu page 3
mS K I N D T L : 0 . 0
D L L V L : S T D
Item
Settings
SKIN DTL
0.0 (normal value) to 1.0
Sets the amount of
Smaller values set a softer skin detail.
skin detail
correction.
DL LVL
LOW, STD (normal value), HIGH
Sets the
Set the amount of DynaLatitude
effects as high level, standard level
DynaLatitude level.
(STD), or low level.
Basic menu page 4
This is displayed when the SET UP switch has been
set to FILE.
FILE: *FL
mSELECT FILE
HISAT
CHG FILE
(YESm4)
For details of this operation, see "Setup Files" (page 62).
Basic menu page 5
This menu is displayed only when an external sync
signal is input to the camera adaptor or VTR connected
to the camera head.
mSC PHASE:999
H PHASE: 100
Item
Settings
SC PHASE
000 (normal value) to 999
Sub carrier phase
adjustment for
when camera is
a)
genlocked.
H. PHASE
000 to 100 (normal value) to 199
Horizontal phase
adjustment for
when camera is
genlocked.
a)
a) This applies when using an external sync signal to
synchronize operation of several cameras (see page 34).
Basic menu page 6
MARKER:
ON
mDUR TIME:
MM:SS
00:00
Item
Settings
MARKER
ON (normal value), OFF
Sets MARKER display ON/OFF.
MARKER is displayed
when this setting is ON
and is not displayed
when it is OFF.
When the setting is ON,
go to Advanced Menu 4
to select the type of
marker (see page 58) .
DUR TIME
00:00 to 59:59 (minute
Sets the recording time
to second)
Setting the recoriding time
See "Setting the
before shooting helps you with
recording time in
making scenes of equal
seconds" and "Setting
duration.
the recording time in
When shooting with displaying
minutes" below.
the recording time of the current
cut in the viewfinder (with the
REC TIME switch set to DUR),
the recording time indication
flashes to remind you that the
recording time has passed.
Setting the recording time in seconds
Move the cursor to DUR TIME, then press the UP/ON
button or DOWN/OFF button.
A value of seconds is displayed under "SS".
MARKER:
ON
mDUR TIME:
MM:SS
00:25
Setting the recording time in minutes
1
Press the MENU/STATUS switch to move the
cursor to DUR TIME, then press the UP/ON
button until the "seconds" value (under "SS")
exceeds 59.
The minute value appears below "MM".
2
Repeat step 1 to set the desired time value.
MARKER:
ON
mDUR TIME:
MM:SS
01:00