3.1 MAINTENANCE SCHEDULE

Follow the calendar intervals. More frequent service is required
when operating in adverse conditions noted below.
Check Oil Level
Change Oil and Oil Filter‡
Clean Spark Arrestor Screen
Service Air Filter
Replace Spark Plug
Change oil after first 30 hours of operation then every season.
*
Change oil and oil filter every month when operating under heavy load or in
high temperatures.
** Clean more often under dirty or dusty operating conditions. Replace air filter
parts if very dirty.

3.2 PRODUCT SPECIFICATIONS

3.2.1 GENERATOR SPECIFICATIONS

Model # ......................................................................005800, 005747
Rated Max. Power ...................................................................8.0 kW**
Surge Power ................................................................................10 kW
Rated AC Voltage ......................................................................120/240
Rated Max AC Load
Current @ 240V .............................................................33.3 Amps**
Current @ 120V .............................................................66.7 Amps**
Rated Frequency .................................................... 60 Hz @ 3600 RPM
Phase ................................................................................ Single Phase
Rated DC Voltage ...................................................................... 12 Volts
Battery Type .................................................................... 10 AH, 12VDC
Model # ......................................................................005797, 005798
Rated Max. Power ...................................................................7.0 kW**
Surge Power .............................................................................8.75 kW
Rated AC Voltage ......................................................................120/240
Rated Max AC Load
Current @ 240V .............................................................29.2 Amps**
Current @ 120V .............................................................58.3 Amps**
Rated Frequency .................................................... 60 Hz @ 3600 RPM
Phase ................................................................................ Single Phase
Rated DC Voltage ...................................................................... 12 Volts
Battery Type .................................................................... 10 AH, 12VDC
Model # ....................................................................................005796
Rated Max. Power ...................................................................6.5 kW**
Surge Power .............................................................................8.13 kW
Rated AC Voltage ......................................................................120/240
Rated Max AC Load
Current @ 240V .............................................................27.1 Amps**
Current @ 120V .............................................................54.2 Amps**
Rated Frequency .................................................... 60 Hz @ 3600 RPM
Phase ................................................................................ Single Phase
Rated DC Voltage ...................................................................... 12 Volts
12
NOTE:
At Each Use
*Every Season/Every 100 Hours
**Every Season/Every 100 Hours
**Every Season/Every 200 Hours
Every Season
** Maximum wattage and current are subject to, and limited by, such factors
as fuel Btu content, ambient temperature, altitude, engine condition, etc..
Maximum power decreases about 3.5% for each 1,000 feet above sea level;
and will also decrease about 1% for each 6° C (10° F) above 16° C (60° F)
ambient temperature.

3.2.2 ENGINE SPECIFICATIONS

Rated Horsepower @ 3600 RPM ....................................................14.5
Displacement ............................................................................... 410cc
Spark Plug Type ...................................Champion RC14YC or Equivalent
Spark Plug Part No. ...................................................................0E7585
Spark Plug Gap ............................................... 0.030 inch or (0.76 mm)
Gasoline Capacity ............................................................ 9 U.S. gallons
Oil Type.................................... See Chart in "Adding Engine Oil" Section
Oil Capacity ................................................ w/ Filter Change = 1.5 Qts.
Oil Filter Part No. . ....................................................................070185B
Run Time/Fuel Consumption-1/2 Load .. 10 Hours / .73 gallons per hour
Class II Emission Certified

3.2.3 EMISSIONS INFORMATION

The Environmental Protection Agency (EPA) requires that this
generator comply with exhaust and evaporative emission standards.
This generator is certified to meet the applicable EPA emission
levels on gasoline. The emission control system on this generator
consists of the following:
• Fuel System
~ Carburetor
~ Fuel Tank/cap
~ Fuel Lines
~ Evaporative Vent Lines
• Exhaust System
~ Exhaust Manifold
~ Muffler
It is important to perform the service specified in the Maintenance
Schedule to ensure that the generator complies with the applicable
emission standards for the duration of its useful life. Additionally,
emissions critical maintenance must be performed as scheduled
in order for the Emissions Warranty to be valid. Emissions critical
maintenance consists of servicing the air filter and spark plugs in
accordance with the Maintenance Schedule. Service and repairs
may be performed by any capable person or repair shop.

3.3 GENERAL RECOMMENDATIONS

The warranty of the generator does not cover items that have been
subjected to operator abuse or negligence. To receive full value
from the warranty, the operator must maintain the generator as
instructed in this manual.
Some adjustments will need to be made periodically to properly
maintain the generator.
All adjustments in the Maintenance section of this manual should
be made at least once each season. Follow the requirements in the
"Maintenance Schedule".
Once a year replace the spark plug and replace the air filter.
A new spark plug and clean air filter assure proper fuel-air
mixture and help the engine run better and last longer.
w/o Filter Change = 1.2 Qts.
• Air Induction System
~ Intake Pipe/manifold
~ Air Filter
• Ignition System
~ Spark plug
~ Ignition module
• Exhaust System
~ Exhaust Manifold
NOTE: