SIGNAL PROCESSING UNIT PFV-SP3300 BACKUP POWER SUPPLY UNIT HK-PSU03 INSTALLATION MANUAL 1st Edition Serial No. 10001 and Higher (PFV-SP3300) Serial No. 10001 and Higher (HK-PSU03)
Page 2
à moins d’être qualifié pour en effectuer d’autres. Pour toute réparation faire appel à une personne compétente uniquement. For the U.S.A (PFV-SP3300) Attention-when the product is installed in Rack: 1. Prevention against overloading of branch circuit...
Manual Structure Purpose of this manual This manual is the installation manual of Signal Processing Unit PFV-SP3300 and its Backup Power Supply Unit HK-PSU03. This manual is intended for use by trained system and service engineers, and describes the information for installation of the unit.
HK-PSU03 Approx. 2 kg AC 240 V IN : 55 A . To prevent overheating of PFV-SP3300, ensure that there is good air circulation around the unit. AC power supply is required a capacity which is commen- . Do not put the unit in a place subject to excessive lamp surate with rush current.
. Do not block the ventilation holes of the unit. . Both of the front and rear sides must be at least 20 cm away from the walls for ventilation and mainte- nance. The outer dimensions of PFV-SP3300 are as shown here: 132.4 17.5...
4. Insert HK-PSU03 into PFV-SP3300 and push it by Before installing the backup power supply unit HK-PSU03 hand as far as it will go. in PFV-SP3300, set the power switch of HK-PSU03 to the 5. Secure HK-PSU03 with the two screws which is “O” position (OFF).
1. The optional board can be installed in any empty slot of PFV-SP3300. 5. Stick the slot label supplied with the PFV-SP3300 onto the board lever. Installing Main Board (Front side) Attach the supplied slot label to the position shown in 1.
Page 9
2. Connect the connector panel to the MB-915 board. 3. Secure the connector panel with the two screws. MB-915 board Screws Connector panel Do not open the slot for an air-cooled effect of this unit. Attach the blank panel to an empty slot. 1-5 (E) PFV-SP3300...
1-6-2. Rack Mounting Procedure Specified rack mounting kit: RMM-10 Explains the procedure for rack mounting by Rack Mount PFV-SP3300 may not be able to be mounted on a 19-inch Kit RMM-10. standard rack using a rack mounting kit other than the specified one.
Page 11
6. Align the crook of the each rack bracket on the side panels of the unit with the rail, then slide the unit 8. Reinstall the front panel. backward. Each rack bracket covers the rails as shown in the figure below. Rack bracket Rack bracket Rail Rail 1-7 (E) PFV-SP3300...
1-7. Matching Connector/Cable 1-8. Signal Inputs/Outputs 1-7. Matching Connector/Cable When external cables are connected to the connectors on the PFV-SP3300 rear panel, the hardware listed below (or the equivalent) must be used. PFV-SP3300 side connector Matching connector/cable Print on Connector type...
For the replacement of the fan, refer to the optionally . Clean the filter on the rear of the front panel periodically available PFV-SP3300 Maintenance Manual. because the filter tends to gather dust (once every two months). Procedure 1.
Page 15
The material contained in this manual consists of information that is the property of Sony Corporation. Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation.