CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.22, ANSI Z21.50 FOR VENTED GAS FIREPLACE.
GT8N
NATURAL GAS
GT8P
PROPANE
Certified for Canadian and United States using ANSI/CSA Methods.
SAFETY INFORMATION
!
If the information in these instructions are not
followed exactly, a fire or explosion may result
causing property damage, personal injury or loss
of life.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS:
● Do not try to light any appliance.
● Do not touch any electrical switch; do not use
any phone in your building.
● Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
● If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by a
qualified installer, service agency or the supplier.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031
$10.00
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

OPERATION INSTRUCTIONS

WARNING
www.napoleonfireplaces.com • ask@napoleon.on.ca
INSTALLATION
1
AND
W415-0619 / B / 03.03.08

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon Torch GT8P

  • Page 1: Operation Instructions

    INSTALLATION OPERATION INSTRUCTIONS CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.22, ANSI Z21.50 FOR VENTED GAS FIREPLACE. GT8N NATURAL GAS GT8P PROPANE Certified for Canadian and United States using ANSI/CSA Methods. SAFETY INFORMATION WARNING If the information in these instructions are not...
  • Page 2: Table Of Contents

    TABLE of CONTENTS PG 2-5 INTRODUCTION 15-17 FINISHING Warranty Door Removal General Instructions Glass Removal General Information Frame/Front Installation Care of Glass and Plated Parts Accent Glass Installation Dimensions LK8 Light Installation (Optional) 5-10 VENTING OPERATING INSTRUCTIONS Venting Lengths and Air Terminal Locations MAINTENANCE Vent Installations Typical Vent Installations - Horizontal Termination...
  • Page 3 ® ® ® ® The following materials and workmanship in your new NAPOLEON® gas fireplace are warranted against defects for as long as you own the fireplace. This covers: combustion chamber, heat exchanger, stainless steel burner, gold plated parts against tarnishing, porcelainized enameled components and aluminum extrusion trims. Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves, thermal switch, switches, wiring, remote controls, ignitor, gasketing, and pilot assembly are covered and NAPOLEON®...
  • Page 4: General Instructions

    GENERAL INSTRUCTIONS THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. Installation practices vary from region to region and it is important to know the specifi cs that apply to your area, for example: in Massachusetts State: •...
  • Page 5: Care Of Glass And Plated Parts

    CARE OF GLASS AND PLATED PARTS The glass is 3/16” ceramic WARNING glass, available from your Napoleon® / Wolf Steel Ltd. Do not substitute materials. Use care when dealer. Clean the glass after handling glass components do not stike, or the fi...
  • Page 6: Vent Installations

    VENT INSTALLATIONS For safe and proper operation of the fi replace follow the venting instruction exactly. Deviation from the minimum or the maximum vertical vent length can create diffi culty in burner start-up and/or carboning. Under extreme vent confi gurations, allow several minutes (5-15) for the fl ame to stabilize after ignition. Vent lengths that pass through unheated spaces (attics, garages, crawl spaces) should be insulated with the insulation wrapped in a protective sleeve to minimize condensation.
  • Page 7: Typical Vent Installations - Horizontal Termination

    TYPICAL VENT INSTALLATIONS - HORIZONTAL TERMINATION MAX FIGURE Allowable 3” vent connections (excluding fi replace and air terminal connections) Rise per foot (recommended) 1/4” Rise per foot (allowable) 0” Horizontal run (If vent run does not include vertical rise) 4” 24”...
  • Page 8: Typical Vent Installations - Vertical Termination

    TYPICAL VENT INSTALLATIONS - VERTICAL TERMINATION FIGURE Allowable 3” vent connections (excluding fi replace and air terminal connections) Rise per foot (recommended) 1/4” Rise per foot (allowable) 0” Vertical run (when not venting horizontally) 24” 19 1/2 FT 3a, 3c Horizontal run 4”...
  • Page 9: Minimum Air Terminal Location Clearances

    MINIMUM AIR TERNMINAL LOCATION CLEARANCES FIGURE 4 W415-0619 / B / 03.03.08...
  • Page 10: Installation/Framing

    INSTALLATION / FRAMING WALL AND CEILING PROTECTION This application occurs when venting through an exterior FIGURE 5 8” wall. Having determined the air terminal location, cut and frame a hole in an exterior wall with a minimum square opening of 8” wide x 8” high. 1.
  • Page 11: Using Flexible Vent Components

    USING FLEXIBLE VENT COMPONENTS FIGURE 9 USE ONLY WOLF STEEL LTD. 3” / 5” FLEXIBLE VENT COMPONENTS. For safe and proper operation of the fi replace, follow the venting ELBOW instructions exactly. All 3" fl exible vent pipe and 5" fl exible vent pipe joints may SPACERS be sealed using high temperature sealant W573-0002 (not supplied) or the high temperature sealant W573-0007 Mill...
  • Page 12: Fireplace Vent Connection

    4. Thread the air terminal connector / vent pipe assembly down through the roof. The air terminal must be located vertically and plumb. Attach the air terminal connector to the roof support, ensuring that the top of the air terminal is 16” above the highest point that it penetrates the roof.
  • Page 13: Gas Installation

    GAS INSTALLATION Proceed once the vent installation is complete. FIGURE 16 Note: All gas connections must be contained within the fi replace when complete. 1. The fi replace is designed to accept a 1/2” gas supply line. The fi replace is equipped with a 1/2”...
  • Page 14: Nailing Tab Installation

    NAILING TAB INSTALLATION Attach the 4 nailing tabs supplied to the sides of the outer shell as illustrated using the 8 self-tapping screws included in the manual baggie. FIGURE 20 FRAMING has been designed to be installed mid-way up a wall. When installing this unit close to the fi nished fl oor, the unit must be raised a minimum of 2”...
  • Page 15: Finishing

    CLEARANCES TO COMBUSTIBLES Minimum clearance to combustible construction from fi replace and vent surfaces: Fireplace framing: - 6” to top - 0” to stand-offs COMBUSTIBLE NON-COMBUSTIBLE (rear and sides) Vent pipe: - 1” BRICK Recessed depth: - 7” 12” MIN. TO 6”...
  • Page 16: Frame/Front Installation

    FRAME/FRONT INSTALLATION 1. Align the two holes in the upper FIGURE 26 portion of the hinge on the control door to those in the bottom trim bracket, secure using two of the #8 x 1/2” hex head screws supplied. Figure 26 2.
  • Page 17: Accent Glass Installation

    ACCENT GLASS INSTALLATION Carefully sprinkle the accent glass onto the glass support ACCENT evenly. Ensure no glass falls into the burner area. If this GLASS happens, insert a clean bag into your vacuum cleaner and BURNER vacuum out the accent glass. Replacement accent glass can be purchased from Wolf Steel Ltd.
  • Page 18: Operating Instructions

    CONSTRUCTION AND SAFETY STANDARD. TITLE 24 DFR, PART 3280. WHEN THIS US STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI/NFPA 501A. REFERENCE #15901 MODEL MODEL CERTIFIED FOR CANADA AND USA GT8N GT8P (NATURAL GAS) (PROPANE) 0-4500FT (0-1370m) ALTITUDE 0-4500FT (0-1370m) 6,000 BTU/h INPUT...
  • Page 19: Maintenance

    MAINTENANCE TURN OFF THE GAS AND ELECTRICAL POWER BEFORE 1. Keep the control compartment, burner, and air shutter opening SERVICING THE FIREPLACE. clean by vacuuming or brushing, at least once a year. 2. Check to see that the main burner ignites when the switch CAUTION: Label all wires prior to disconnection when servicing for the burner is turned on.
  • Page 20: Replacements

    REPLACEMENTS Contact your dealer for questions concerning prices and availability WARNING of replacement parts. Normally all parts can be ordered through your Napoleon® dealer or distributor. When ordering replacement parts always give the following Failure to position the parts in accordance with these diagrams or information: failure to use only parts specified approved with this appliance may result in property damage or personal injury.
  • Page 21 TROUBLE SHOOTING GUIDE BEFORE ATTEMPTING TO TROUBLESHOOT PURGE YOUR UNIT AND INITIALLY LIGHT THE IGNITOR AND THE MAIN BURNER WITH THE GLASS DOOR OPEN SYMPTOM PROBLEM TEST SOLUTION Electrode sparks, burner Hot and neutral wires are reversed - Connect the hot wire to the black wire. Connect the neutral wire to ignites, electrode at control module.
  • Page 22 W415-0619 / B / 03.03.08...