OPERATING INSTRUCTIONS

Indicator lights on display panel

NOTE: The display panel of the indoor unit you purchased
may look like one of the following:
2
1 1
4
3
auto
t imer
defro st
io n
Signal
receptor
(A )
run
auto
time r
de f.
(B )
r un
io n
timer
d ef.
(C )
6
Auto indicator:
1
Lights up when the air conditioner is in AUTO operation.
2
Timer indicator:
Lights up when TIMER is set to ON/OFF
3
Defrost indicator:
(For cooling and heating models only):
Lights up when the air conditioner starts defrosting
automatically or when the warm air control feature is
activated in heating operation.
4
Ion Indicator:
Lights up when Ion feature is activated and the Ionizer can
generate suffi cient anions to fi ll the room with refreshing and
natural air.
NOTE: This function is only available for units with the Ionizer
option.
Digital display:
Displays the current temperature setting and malfunction/
protection code when the air conditioner is in operation.
Frequency display:
This display is separated into fi ve zones. The zones light up
based on the compressor current frequency. For example, a
higher frequency will light up more zones.
RUN indicator lamp:
run
This lamp lights up when the air conditioner is in operation.
AUTO indicator lamp:
Lights up whilst the Auto setting is in use.
ION indicator lamp (optional function):
ion
Lights up when the Clean Air feature is activated and the
Ionizer can generate suffi cient anions to fi ll the room with
refreshing and natural air.
TIMER indicator lamp:
timer
Lights up during Timer operation
DEFROST indicator lamp:
def.
(For cooling and heating models only):
Lights up when the air conditioner starts defrosting
automatically or when the warm air control feature is
activated in heating operation.
OPERATING INSTRUCTIONS
NOTE: This manual does not include Remote Controller Operations. See the Remote Controller Instruction booklet included
with the unit for details.

Operating temperature

Mode
Cooling operation
Temperature
Room temperature
≥17ºC
0ºC - 50ºC
-15ºC - 50ºC
Outdoor temperature
(For models with low
temperature cooling system)
CAUTION
1. If air conditioner is used outside of the above conditions, certain safety protection features may come into operation
and cause the unit to function abnormally.
2. Room relative humidity must be less than 80%. If the air conditioner operates in excess of this fi gure, the surface of the
air conditioner may attract condensation. Please set the vertical air fl ow louvre to its maximum angle (vertically to the
fl oor), and set on HIGH fan mode.
3. Optimum performance will be achieved when used within these operating temperatures.
Suggestion: If the unit includes an Electric Heater, and the outside ambient temperature is below 0ºC, we strongly
recommend keeping the machine plugged in to ensure it runs smoothly.

Manual operation

Manual operation can be used temporarily in case the remote controller is disabled or maintenance is required.
Panel
Man ual control
AUTO/COOL
butt on
Heating operation
Drying operation
≤30ºC
>10ºC
-15ºC - 34ºC
0ºC - 50ºC
NOTE: The unit must be turned off before operating the
manual control button. If the unit is operational, continue
pressing the manual control button until the unit switches
off.
1. Open and lift the front panel up until it remains fi xed with
a clicking sound.
2. One press of the manual control button will lead to the
forced AUTO operation. If the button is pressed twice
within fi ve seconds, the unit will operate under forced
COOL operation.
3. Close the panel fi rmly to its original position.
CAUTION
• This button is used for testing purposes only.
Unauthorised use is not recommended.
• To restore remote controller access, use the remote
controller directly.