The first digit indicates the swing above the set point; the second digit
indicates the swing below the set point, as indicated below:
"ABOVE
Digit #1
1 =
0.0 deg. F. (0.0 deg. C.)
2 = +0.5 deg. F. (0.3 deg. C.)
3 = +0.75 deg. F. (0.4 deg. C.)
4 = +1.0 deg. F. (0.6 deg. C.)
5 = +1.5 deg. F. (0.8 deg. C.)
6 = +2.0 deg. F. (1.1 deg. C.)
7 = +2.5 deg. F. (1.4 deg. C.)
NOTE: DO NOT SELECT 1,1
The following are suggested entries for digits one and two respectively in
Field 11 for different types of heating systems:
1,4 = Hot water heat [default]
4,1 = Hot air or electric heat
6,4 = Gravity feed systems.
Ask the homeowner or HVAC installer about the type of system at the
premises.
Field 12: Announce Thermostat #2 Temperature
1 = Announce thermostat #2 temperature as part of the 4286 status
report for the security system.*
0 = Do not announce thermostat #2 temperature. [default]
*If a second 4500 thermostat is installed it is recommended that this field be
programmed to enable announcement of ambient temperature so that
premises temperature can be monitored when user is away.
Section 4. Programming the 4286 to Add Thermostat(s)
Temperature Span (Swing)
1 =
2 = -0.5 deg. F. (-0.3 deg. C.)
3 = -0.75 deg. F. (-0.4 deg. C.)
4 = -1.0 deg. F. (-0.6 deg. C.)
5 = -1.5 deg. F. (-0.8 deg. C)
6 = -2.0 deg. F. (-1.1 deg. C)
7 = -2.5 deg. F. (-1.4 deg. C.)
"BELOW"
Digit #2
0.0 deg. F. ( 0.0 deg. C.)