4500 Thermostat Installation Instructions
If you are installing the 4500 in a heat only system, the setup will look like
Figure 4 below.
R
HVAC
System
Figure 4. 4500 Thermostat with Heating System Only
Some heating systems, such as the forced-air type, have a fan (connections
are shown). Other heat-only systems may not include a fan, in which case
the fan connections are not used.
If you are installing the 4500 in a cooling only system, the setup will look like
Figure 5 below.
Rc
HVAC
System
Figure 5. 4500 Thermostat with Cooling System Only
3-4
4500
THERMOSTAT
5 3
6
8
OUT
Heat (W)
Fan (G)
4500
THERMOSTAT
5 4
7
8
OUT
Cool (Y)
Fan (G)
4286
PHONE
MODULE
R
PREMISES
THERMOSTAT
IN
W
Heat (W)
Fan (G)
4286
PHONE
MODULE
Rc
PREMISES
THERMOSTAT
IN
Cool (Y)
Fan (G)
G