D. Go to the Equipment Test screen (Figure 5.2). Following the menus, turn each equipment
output relay ON and OFF to check that on-board relays are functional.
For HVAC Techs Only!
Setup
Equipment Test
Locked
E. Go to the Zone Module test screen. Activate all zone dampers and perimeter heat relays (if
perimeter heat option installed).
Equipment
Zone Module
Environmental
F. Go to the Environmental test screen and activate the bypass damper.
G. Go to the Panel Setup screen and configure the control module according to your
installation.
For HVAC Techs Only!
Setup
Equipment Test
NOTE: During the panel setup, you must select a Must-Service zone. An equipment call
from this zone is given enough weight to activate first stage. You may want to select a zone
at close proximity to the panel during the system test to facilitate the equipment cycle test.
H. Connect RH & RC terminals to power the equipment relays.
I. Go to the Schedule menu and select Schedule: Normal.
12:00A Fri Jan01/99
System Off
Fan On
Schedule:Suspended
Suspended
J. Go to the Main Menu:
K. Observe that all zone damper LEDs come ON and that all zone dampers are open.
SlimZone Premier
Equipment
3
Zone Module
Environmental
Note: Must hold button
Zone #01 Room 76
Heat 68 Cool 70
2
Auto Mode
Calls: Fan
Press
or
to select zone
Equipment
Zone Module
Environmental
NOTE: Leave the bypass damper closed at this stage.
Setup
Panel
2
Bypass
Options
Schedule: Suspended
4
Programming
12:00A Fri Jan01/99
System Off
Fan On
Schedule: Normal
1
1
for 10 seconds to unlock these menu options.
Zone #01
Exercise Damper
1
Perimeter Heat
Outdoor
73 Duct 74
Pressure 0.03 in. WC
3
Bypass - Normal
2
2
Press
Select the following:
- System Off mode
- Fan On to enable constant fan
Equipment Relay
W4 Off
W3 Off
Damper #01
Open
2
Perimeter Heat #01
3
Off
3
Press button
toggle damper position
System Type:
Heat pump
Refer to Figure 5.3
Schedule: Normal
until Normal is selected
1