ADJUSTMENTS
PRESSURE REGULATOR:
1. Turn off main gas to unit.
2. Remove broiler bottom (6 sheet metal screws).
3. Remove pilot line valve from manifold.
4. Install a fitting appropriate to connect a manometer.
5. Be sure both valves are in the "OFF" position and turn on main gas.
6. Ignite rear burner by hand and then front burner.
7. With burners full on, read manometer. It should read 4" W.C. for natural gas and 10" W.C. for
propane gas. (If pressure is satisfactory, go to Step 10.)
8. Remove cap from top of regulator.
9. With a screwdriver, rotate adjustment screw "clockwise" to increase, or "counterclockwise" to
decrease, pressure until manometer shows correct reading.
10. Turn burner valves to "OFF" position.
11. Turn main gas off.
12. Remove manometer fitting.
13. Replace pilot valve in manifold.
14. Put bottom on.
15. Turn on main gas.
16. Light pilot.
17. Verify proper burner ignition.
TROUBLE SHOOTING:
Problem
Unit will not turn on
Burners produce excessive
carbon deposits
Pilot produces excessive
carbon deposits
Pilot will not stay ignited
SALAMANDER RADIANT BROILER
SECTION THREE — SERVICE
PAGE 2
Look for —
main gas supply "OFF."
— pilot out.
— incorrect gas type.
— incorrect supply pressure.
— primary air not adjusted properly.
— incorrect orifices.
— pilot gas not adjusted properly.
— incorrect gas type.
— incorrect supply pressure.
— pilot gas not adjusted properly.
— clogged orifice.
— draft condition.
— improper ventilation system.
— air in gas line.