Payne Gas furnace Owner's Manual
Payne Gas furnace Owner's Manual

Payne Gas furnace Owner's Manual

Induced combustion gas furnace
Hide thumbs Also See for Gas furnace:

Advertisement

NOTE TO INSTALLER:
THIS MANUAL MUST BE LEFT WITH THE
EQUIPMENT USER.
USER: PLEASE READ ALL INSTRUCTIONS
IN THE MANUAL AND RETAIN ALL
MANUALS FOR FUTURE REFERENCE.
ISO 9001:2000
REGISTERED
Use of the AHRI Certified TM Mark indicates a
manufacturer's participation in the program. For
verification of certification for individual products,
go to www.ahridirectory.org.
INDUCED COMBUSTION GAS FURNACE
Owner's Manual
A10257
Always Ask For
WARNING
!
FIRE OR EXPLOSION HAZARD
Failure to follow warnings could result in injury, death, or
property damage.
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
- -Do not try to light any appliance.
- -Do not touch any electrical switch; do not use any
phone in your building.
- -Leave the building immediately.
- -Immediately call your gas supplier from a near by
phone. Follow the gas supplier's instructions.
- -If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
WARNING
!
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in personal
injury and/or death.
Carbon Monoxide is invisible, odorless, and toxic! Payne
Heating and Cooling Systems recommends a carbon
monoxide alarm in your home, even if you do not own a
gas appliance. Locate the carbon monoxide alarm in the
living area of your home and away from gas appliances and
doorways
to
attached
manufacturer's instruction included with the alarm.
WARNING
!
ELECTRICAL OPERATION HAZARD
Failure to follow this warning could result in personal injury,
death, or property damage.
Do not use this furnace if any part has been under water. A
flood- -damaged furnace is extremely dangerous. Attempts to
use the furnace can result in fire or explosion. A qualified
service agency should be contacted to inspect the furnace and
to replace all gas controls, control system parts, electrical parts
that have been wet or the furnace if deemed necessary.
1
garages.
Follow
the
alarm

Advertisement

Table of Contents
loading

Summary of Contents for Payne Gas furnace

  • Page 1: Combustible Materials, Gasoline Warning

    INDUCED COMBUSTION GAS FURNACE Owner’s Manual NOTE TO INSTALLER: WARNING THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. FIRE OR EXPLOSION HAZARD Failure to follow warnings could result in injury, death, or USER: PLEASE READ ALL INSTRUCTIONS property damage.
  • Page 2: Table Of Contents

    ELBOW OF COMFORT MAIN LIMIT SWITCH (BEHIND GAS VALVE) PRESSURE Congratulations! Your new, higher efficiency gas furnace is a SWITCH sound investment which will reward you and your family with BLOCKED VENT SWITCH years of warm memories winter after winter.
  • Page 3: Safety Considerations

    STARTING YOUR FURNACE NOTE: The qualified installer or agency must use only factory- -authorized replacement parts, kits, and accessories when Your furnace uses an automatic, hot surface ignition system to light modifying this product. the burners each time the thermostat signals the furnace to start. This furnace contains safety devices which must be manually reset.
  • Page 4 A02267 A06188 Fig. 8 - - Control Switch to ON Fig. 4 - - Close Valve 8. Replace the outer door and tighten the thumbscrew. See Fig. 3. Turn OFF electrical supply to the furnace. See Fig. 5. A92185 Fig. 5 - - Turn Off Electrical Supply 4.
  • Page 5: Shutting Down Your Furnace

    the furnace’s heat exchanger. After a time delay of approxim- CAUTION ately 25- -45 seconds the furnace blower is switched on. NOTE: If the main burners fail to ignite, the furnace control CUT HAZARD system will go through three more ignition cycles. Then if burners fail to ignite, the system will lockout.
  • Page 6: Combustion Area And Vent System

    FILTER QUANTITY AND SIZE * FURNACE CASING WIDTH FILTER TYPE* IN (MM) SIDE RETURN BOTTOM RETURN IN (MM) IN (MM) (1) 16 x 25 (1) 14 x 25 3/4” (19 mm) thick washable or 4--- 5/16” (110 mm) 14--- 1/2 (368) (406 x 635) (356 x 635) thick media--- type...
  • Page 7: Before You Request A Service Call

    S Is the electrical power supply switch on? Is the blower access WARNING door firmly in place? Are any fuses blown? (There is a fuse on the furnace control.) Has a circuit breaker tripped? CARBON MONOXIDE POISONING HAZARD S Is the manual shut- -off valve in the gas supply pipe leading to Failure to follow this warning could result in personal the furnace open? Does the lever point in the same direction that injury or death.
  • Page 8: Installation Data

    In addition to the type of routine maintenance you might be willing to perform, your furnace should be inspected regularly by a properly trained service technician. You should work with your dealer or service technician to assure your inspection includes the following at a minimum.

Table of Contents