Mitsubishi Electric SEZ-KD18NA Specifications page 3

18,000 btu/h horizontal-ducted indoor unit for mxz multi-zone heat-pump systems
Hide thumbs Also See for SEZ-KD18NA:

Advertisement

Note2
Required space for service and maintenance
Model
SEZ-KD09NA
SEZ-KD12NA
SEZ-KD15NA
SEZ-KD18NA
Note1.Use M10 screw for the suspension bolt (field supply).
2.Keep the service space for the maintenance at the bottom.
3.This chart indicates for SEZ-KD15NA model,which has 3 fans.
SEZ-KD09,12NA models have 2 fans.
SEZ-KD18NA models have 4 fans.
4.In case an inlet duct is used,remove the air filter(supply with
the unit), then install the filter(field supply) at suction side.
C SD - SEZ-KD18NA - 200903 © MITSUBISHI ELECTRIC / HVAC 2009
DImENSIoNS: SEZ-KD18NA
345(13-19/32)
15(19/32)
2XE-ø2.9(1/8)
Air
outlet
10(13/32)
49
625(Suspension bolt pitch)
(1-15/16)
(24-5/8)
Drain pipe(O.D.ø32(1-1/4))
23(29/32)
10(13/32)
116
70
(4-19/32)
(2-25/32)
270(10-21/32)
2X2-ø2.9(1/8)
Refrigerant piping
Refrigerant piping
1
2
flare connection (gas)
flare connection (liquid)
175±5(6-29/32±7/32)
(Actual length)
Access door
A
B
C
D
E
F
G
700
752
798
660
600
800
7
(27-9/16)
(29-5/8)
(31-7/16)
(26)
(23-5/8)
(31-1/2)
900
952
998
860
800 1000
9
(35-7/16)
(37-1/2)
(39-5/16)
(33-7/8)
(31-1/2)
(39-3/8)
1100
1152
1198
1060
1000
1200
11
(43-5/16)
(45-3/8)
(47-3/16)
(41-3/4)
(39-3/8)
(47-1/4)
Drain pipe(O.D.ø32(1-1/4))
(Emergency draining)
Suspension bolt hole
4-14X30(9/16X1-3/16) Slot
Air
inlet
Knockout hole ø27(1-3/32)
(Indoor/outdoor connecting line)
700(27-9/16)
677(26-21/32)
Control box
Terminal block (Indoor/outdoor connecting line)
Terminal block (Remote controller transmission line)
Drain pipe(O.D.ø32(1-1/4))
(Spontaneous draining)
Less than 300
(11-13/16)
Drain hose (I.D.ø32(1-1/4))
<accessory>
H
J
K
L
M
N
Gas pipe
1
660
500
839
790
5
16
(26)
(19-11/16)
(33-1/16)
(31-1/8)
ø9.52(3/8)
860
700
1039
990
7
20
(33-7/8)
(27-9/16)
(40-29/32)
(39)
ø12.7(1/2)
1060
900
1239
1190
9
24
(41-3/4)
(35-7/16)
(48-25/32)
(46-7/8)
Unit : mm(in.)
37(1-15/32)
100(3-15/16)
20(13/16)
157.5 (6-7/32)
12(1/2)
37(1-15/32)
L-ø2.9(1/8)
Air filter
Knockout hole ø27(1-3/32)
(Remote controller transmission line)
Ceiling surface
Access door
Make the access door at the appointed position properly
for service maintenance.
mm(in.)
Liquid pipe
2
ø6.35(1/4)
3400 Lawrenceville Suwanee Rd
Suwanee, GA 30024
Tele: 678-376-2900 • Fax: 800-889-9904
Toll Free: 800-433-4822 (#3)
www.mehvac.com
Specifications are subject to change without notice.