Install the hard drive.
3.
Determine the status of the hard drive from the hot-plug hard drive LEDs
4.
LEDs" on page 8).
Resume normal server blade operations.
5.

Mezzanine card option

Optional mezzanine cards provide additional I/O support. For mezzanine card locations, see "System
board components (on page 9)."
For mezzanine card signal mapping, see "Interconnect bay numbering and device mapping (on page 26)"
and the installation instructions that ship with the server blade.
Optional mezzanine cards are classified as Type I mezzanine cards and Type II mezzanine cards. The card
type determines where it can be installed in the server blade:
Install Type I mezzanine cards on any mezzanine connector.
Install Type II mezzanine cards on Mezzanine 2 connector or Mezzanine 3 connector only.
Because mezzanine cards are supported on multiple server blade models, the mezzanine card may have
captive screws that are not required to secure it to the server blade. When installing a mezzanine card in this
server blade, only two captive screws are required.
WARNING:
internal system components to cool before touching them.
To install the component:
Power down the server blade (on page 14).
1.
Remove the server blade (on page 15).
2.
Remove the access panel (on page 16).
3.
To reduce the risk of personal injury from hot surfaces, allow the drives and the
("SAS and SATA hard drive
Hardware options installation 49