Technical Specifications
Electrical characteristics Maximum heat
Safety
Emissions
Immunity
Management
Services
Nonoperating/Storage
relative humidity
dissipation
DC Voltage
Maximum power rating
Notes
CE Labeled; cUL Certified; UL Listed; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of
Laser Products-Part 2; IEC 60825; IEC 60950-1:2001 (with CB Report); CAN/CSA-C22.2 No. 60950-1-03;
Anatel; ULAR; GOST; EN 60950-1/A11; FDA 21 CFR Subchapter J; NOM; UL 60950-1:2003; EN 60950-
1:2001; ROHS Compliance
VCCI Class A; EN 55022 Class A; VCCI V-3/2000.04; ICES-003 Class A; AS/NZS CISPR22 Class A; EMC
Directive 2004/108/EC; FCC (CFR 47, Part 15) Class A
Generic
EN
ESD
Radiated
EFT/Burst
Surge
Conducted
Power frequency
magnetic field
Voltage dips and
interruptions
Harmonics
Flicker
IMC - Intelligent Management Center; command-line interface; out-of-band management (serial RS-232C);
SNMP Manager; Telnet; RMON1; FTP; in-line and out-of-band; terminal interface (serial RS-232C); modem
interface
3-year, 4-hour onsite, 24x7 coverage for hardware (U7M17E)
3-year, 4-hour onsite, 24x7 coverage for hardware (U7M19E)
3-year, 24x7 SW phone support, software updates (U7M25E)
4-year, 4-hour onsite, 13x5 coverage for hardware (U7M30E)
4-year, 4-hour onsite, 24x7 coverage for hardware (U7M32E)
4-year, 4-hour onsite, 24x7 coverage for hardware (U7M45E)
4-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (U7M39E)
4-year, 24x7 SW phone support, software updates (U7M38E)
5-year, 4-hour onsite, 13x5 coverage for hardware (U7M43E)
5-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (U7M52E)
5-year, 24x7 SW phone support, software updates (U7M51E)
3 Yr 6 hr Call-to-Repair Onsite (U7M22E) 3 Yr 6 hr Call-to-Repair Onsite (U7M22E) 5-year, 4-hour onsite,
24x7 coverage for hardware, 24x7 software phone (UW992E)
DA - 13785 Worldwide — Version 24 — May 12, 2014
5% to 95%, non-condensing
8123 BTU/hr (8569.77 kJ/hr)
-48 to -60 VDC
2380 W
Maximum power rating and maximum heat dissipation are the worst-case
theoretical maximum numbers provided for planning the infrastructure with
fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all
modules populated.
ETSI EN 300 386 V1.3.3
EN 55024:1998+ A1:2001 + A2:2003
EN 61000-4-2; IEC61000-4-2
EN 61000-4-3; IEC61000-4-3
EN 61000-4-4; IEC61000-4-4
EN 61000-4-5; IEC61000-4-5
EN 61000-4-6; IEC61000-4-6
IEC 61000-4-8; EN61000-4-8
EN 61000-4-11; IEC61000-4-11
EN 61000-3-2, IEC 61000-3-2
EN 61000-3-3, IEC 61000-3-3