Rack Mounting; Mounting In An Eia Standard Rack - Yamaha XS250 Owner's Manual

Yamaha power amplifier owner's manual
Hide thumbs Also See for XS250:
Table of Contents

Advertisement

Rack Mounting

Mounting in an EIA standard rack

If multiple high-power amp units are mounted in a rack with poor ventilation, the heat from the amps will cause the
interior of the amp to become very hot, causing the performance of the amps to be impaired. In particular, when
mounting in a rack whose back can not be left open, mount according to the following instructions.
Rack: Leave a gap of 10 cm or more between the rear panel of the rack and the rear panel of the amplifier.
Fan: Use a fan with 1.5 m
Mounting: Install the fan kit on the top slot or the top panel of the rack and install a blanking panel between two
amps.
Example of mounting
The figure on the left below shows an example of a fan kit (panels and two fans) on the top slot of the rack. The fans
are Minebia 3115PS-12T-B30 (with 0.9 m
The figure on the right below is a dimensional diagram of a panel on which two 3115PS-12T-B30 are installed.
Fan kit
XS350/XS250
Blanking panel
XS350/XS250
Blanking panel
XS350/XS250
10
3
/min or more maximum wind and 5 mmH
3
/min maximum wind and 5 mmH
O or more maximum static pressure.
2
O maximum static pressure).
2
78
71.5 0.1
248
463
480
Unit: mm

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xs350

Table of Contents