Installation - Honeywell Enviracaire Elite HE225A Product Data

Whole-house air quality system bypass flow-through humidifiers
Hide thumbs Also See for Enviracaire Elite HE225A:
Table of Contents

Advertisement

2 )
( 2 3
/ 8
9 - 1
1 2
( 3 0
5 )
Fig. 1. Dimensions of HE225A,B in in. (mm).
5 )
( 2 3
/ 4
9 - 1
1 3
- 9 /
1 6
( 3 4
5 )
Fig. 2. Dimensions of HE265A,B in in. (mm).
Approvals:
Underwriters Laboratories Inc. Listing: 56 BL.
Canadian Underwriters Laboratories Inc. Listing: 56 BL.
Standard:
Air Conditioning and Refrigeration Institute Tested:
Standard 610.
1 1
- 7 /
1 6
( 2 9
0 )
1 2
( 3
1 6
- 9 /
1 3
5 )
( 3 4
6 (152)
DIAMETER
M14818
1 2
( 3 0
5 )
1 5
4
- 3 /
1 6
5 )
( 4 2
6 (152)
DIAMETER
M14819
HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIERS
Models:
HE225A TRADELINE® and HE265A TRADELINE®
Bypass Flow-through Humidifier package includes
humidifier pad, mounting template, self-piercing saddle
valve, 24 Vac transformer, H8908B Convertible
Humidity Control.
HE225B TRADELINE® and HE265B TRADELINE®
Bypass Flow-through Humidifier package includes
humidifier pad, mounting template, self-piercing saddle
valve, 24 Vac transformer, H1008A Automatic Humidity
Control with HumidiCalc+™ Software.
Accessories:
Current Sensor Relay, part no. 32001754-001.
C7089H Outdoor Temperature Sensor.
- 7
/ 1 6
H8908B Convertible Humidity Control.
1 6
)
H1008A Automatic Humidity Control with HumidiCalc+™
Software (software calculates dewpoint to prevent moisture
condensation).
HC22E Antimicrobial Humidifier Pad (HE225A,B only).
HC26E Antimicrobial Humidifier Pad (HE265A,B only).
HumidiCalc+™ Humidifier Sizing Software (software
calculates required humidifier capacity for application).
PC8900 Control.
S688 Sail Switch.

INSTALLATION

WARNING
Hazardous Voltage.
Can cause personal injury or equipment damage.
Do not cut or drill into any air conditioning line or
electrical accessory.
CAUTION
Freezing Water, Flooding or Static Pressure
Hazard.
Can cause water damage to home or permanent
equipment damage.
- 5
• The humidifier must be located where the ambient
/ 1
( 3
6
9 0
)
temperature is above 32°F and below 160°F (0°C
and 71°).
• Be sure supply plenum static pressure is no greater
than 0.3 in. wc and water pressure is no greater
than 126 psi.
IMPORTANT
To assure optimal product performance, be sure the
template is level before marking location.
1. Determine the best location for the humidifier and draw
a level line on the plenum. See Fig. 3.
IMPORTANT
Mount the humidifier at least 3 in. (76 mm) above the
furnace jacket to allow adequate space for the
solenoid valve and drain line. Check that there is
adequate space above the humidifier to remove and
install the humidifier cover.
3
68-0244-1