Burner And Nozzle Specifications - Hotpoint HW150GW Instructions For Installation And Use Manual

50cm free standing gas cooker creda collection
Table of Contents

Advertisement

Burner and Nozzle Specifications

Table 1
Burner
Diameter
(mm)
Fast
100
(Large)(R)
Semi Fast
75
(Medium)(S)
Auxiliary
51
(Small)(A)
Oven
-
Grill
-
Supply
Pressures
*
At 15°C and 1013 mbar- dry gas
**
Propane
P.C.S. = 50,37 MJ/Kg
***
Butane
P.C.S. = 49,47 MJ/Kg
Natural
P.C.S. = 37,78 MJ/m
S
S
A
R
HW170GK
HW170GW
HW150GW
8
Thermal Power
kW (p.c.s.*)
Nominal
Reduced
94
3,00
0,7
69
1,90
0,4
46
1,00
0,4
2,60
0,6
2,50
1,3
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
3
Liquid Gas
By-Pass
Nozzle
1/100
1/100
(mm)
(mm)
***
41
87
218
30
70
138
30
52
73
36
75
189
63
80
182
28-30
20
35
Natural Gas
Flow*
Nozzle
g/h
1/100
**
(mm)
214
128
136
104
71
76
186
123
179
122
37
20
25
17
45
25
Flow*
l/h
286
181
95
248
238

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hw170gwHw170gk

Table of Contents