Forced Operation; Test Operation - LG AS-W0964DH0/GH0 Manual

Exploded view
Hide thumbs Also See for AS-W0964DH0/GH0:
Table of Contents

Advertisement

Operation
Auto restarting operation
• When the power is restarted after a sudden power failure while in appliance operation, the mode before the
power failure is kept on the memory and the appliance automatically operates in the mode on the memory.
• Operation mode that is kept on the memory
- State of operation ON/OFF
- Operation mode/setting temp./selected airflow speed
- Sleep timer mode/remaining time of sleep timer
- Chaos Swing

Forced operation

• To operate the appliance by force in case that the remote control is lost, the forced operation selection switch
is on the main unit of the appliance to operate the appliance in the standard conditions.
• The operation condition is set according to the outdoor temp. and intake air temperature as follows.
Indoor temp.
over 24°C
21~24°C
below 21°C
❈ The unit select before operating mode in 3 hours.

Test Operation

• Press the Tact Switch for compulsory operation of the main body for 3 seconds in order to operate in the trial
operation mode.
- Operation mode: Cold
- Indoor pan: Strong wind
- COMP frequency: Step 5
- COMP compulsorily operates for about 18 minutes irrespective of indoor temperature.
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Operating Mode
Cooling
Healthy Dehumidification
Heating
- 38 -
Setting speed of
Setting temp.
indoor fan
22°C
High speed
23°C
24°C