Download Print this page

Honeywell HE360B Product Data

Powered flow-through humidifier
Hide thumbs Also See for HE360B:

Advertisement

HE360
The HE360A,B Powered Flow-Through Humidifiers work with
the warm air furnace blower to provide humidification for the
whole house. The HE360A,B works with virtually any
Honeywell humidity control, and can be integrated to the
temperature control in the home, when controlled by the
Honeywell Perfect Climate Comfort Center™ control.
®U.S. Registered Trademark
Copyright © 1999 Honeywell Inc. • All Rights Reserved
• Capable of humidifying the largest areaup to 4200
sq ft (390 sq m)of any Honeywell flow-through
humidifier.
• Includes the PerfectFlo™ water distribution tray for
optimal efficiency and water usage.
• Proven technology used for high performance
humidification.
• Narrower footprint than popular compatible model
while maintaining a common humidifier pad and
comparable humidification performance.
• Interior components designed for quick maintenance
and service.
• HE360A Humidifier includes a convertible humidity
control that mounts on the wall or duct for more
flexibility.
M12807
• HE360B Humidifier includes the Automatic Humidity
Control with HumidCalc+™ that automatically adjusts
humidity level and eliminates moisture build-up.
• Perfect Climate Comfort Center™ control can be
installed to replace both the thermostat and humidity
control for improved aesthetics and convenience.
• Continuous flushing reduces the maintenance
frequency.
Application........................................................................... 1
Features .............................................................................. 1
Specifications ...................................................................... 2
Installation ........................................................................... 3
Wiring Humidifier................................................................. 4
Checking Installation ........................................................... 6
Operating Humidifier ........................................................... 6
Operation ............................................................................ 6
Maintenance........................................................................ 7
Checkout Procedure ........................................................... 8
Troubleshooting .................................................................. 8
Replacement Parts.............................................................. 9
68-0194-2

Advertisement

loading

Summary of Contents for Honeywell HE360B

  • Page 1 The HE360A,B works with virtually any • Continuous flushing reduces the maintenance Honeywell humidity control, and can be integrated to the frequency. temperature control in the home, when controlled by the Honeywell Perfect Climate Comfort Center™...
  • Page 2 Honeywell Inc., 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386 (612) 951-1000 In Canada—Honeywell Limited/Honeywell Limitée, 155 Gordon Baker Road, North York Ontario M2H 3N7. International Sales and Service Offices in all principal cityies of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
  • Page 3 HE360A,B POWERED FLOW-THROUGH HUMIDIFIER T A L R I Z 1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. H I G 2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application.
  • Page 4 HE360A,B POWERED FLOW-THROUGH HUMIDIFIER 1. Wire the current sensing relay or sail switch. CLIP CLIP 2. Connect only the two yellow wires to the humidity control (red wire connections are not used for mechanical humidity control). See the typical wiring diagrams in Fig.
  • Page 5 HE360A,B POWERED FLOW-THROUGH HUMIDIFIER MECHANICAL HUMIDISTAT 120 VAC HUMIDIFIER YELLOW WIRES SAIL SWITCH POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 24V WIRING. M12685 Fig. 8. Typical wiring diagram of sail switch with humidifier. ROOM THERMOSTAT DEHUM DEHUM YELLOW YELLOW RELAY...
  • Page 6 The Automatic Humidity Control with HumidCalc+™ requires initial adjustment when first installing the HE360B. Set the frost factor dial to 5 and use Table 2 to adjust the frost factor, one setting at a time, 1. Open the saddle valve.
  • Page 7 HE360A,B POWERED FLOW-THROUGH HUMIDIFIER Table 2. Recommended Frost Factor Adjustment. Humidity Level Recommended Setting Insufficient humidity Increase the frost factor dial be one setting Condensation on windows Reduce the frost factor dial by one setting. 3. Remove the humidifier pad assembly from the humidifier by grasping the tray and pulling it toward A regular maintenance program prolongs the life of the you.
  • Page 8 HE360A,B POWERED FLOW-THROUGH HUMIDIFIER 1. Turn on the humidifier power and water supply. 2. Turn the humidity control to its highest setting and Turn off the humidifier water supply and the humidity set the thermostat to 10°F (12°C) above the room control while on vacation.
  • Page 9 HE360A,B POWERED FLOW-THROUGH HUMIDIFIER Refer to Fig. 12 and Table 4 when ordering replacement parts. Table 4. List of Replacement Parts for HE360. Feed Tube Nozzle 32000408-001 Water Distribution Tray 32001630-001 Solenoid Valve Assembly (Includes water feed tube) 32001876-001 Humidifier Pad HC26A1008 PWB Assembly 32001676-001...
  • Page 10 HE360A,B POWERED FLOW-THROUGH HUMIDIFIER THE HE360A INCLUDES THE H908A CONVERTIBLE HUMIDITY CONTROL. M16416 THE HE360B INCLUDES THE H1008A AUTOMATIC HUMIDITY CONTROL. Fig. 12. Exploded view of humidifier parts. 68-0194—2...
  • Page 11 68-0194—2...
  • Page 12 Home and Building Control Home and Building Control Honeywell Asia Pacific Inc. Honeywell Inc. Honeywell Limited-Honeywell Limitee Room 3213-3225 Honeywell Plaza 155 Gordon Baker Road Sun Hung Kai Centre P.O. Box 524 North York, Ontario No. 30 Harbour Road Minneapolis, MN 55408-0524...

This manual is also suitable for:

He360a