Advertisement

Available languages

Available languages

HE360 Humidifier and
Installation Kit
69-2631ES-01

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell HE360

  • Page 1 HE360 Humidifier and Installation Kit 69-2631ES-01...
  • Page 2 Congratulations! You have just made a great investment in improving the comfort of your home. APPLICATION This kit contains your new Honeywell HE360 Humidifier, H8908 Humidistat and all the accessories required for installation. INSTALLATION Preparing for the Installation Be sure to identify all the required (Table 1) accessories (included) and make sure the appropriate tools are available before beginning the installation.
  • Page 3: Table Of Contents

    HE360 HUMIDIFIER AND INSTALLATION KIT Table 1. Included Accessories. Quantity Accessory 1 bag Connecting and mounting hardware: Wire nuts (4) No. 8 sheet metal screws (18) Drain tube clamp Feed tube mounting clamps (6) Brass inserts (2) Plastic compression rings (2)
  • Page 4 • Select location with access to a floor drain to provide drainage for air conditioner condensation and humidifier drainage. • If you do not have a drain available, we recommend that you install the Honeywell Whole House Drum or Disk Humidifier. Make sure that the 10 ft (3.1m) of drain tubing is adequate to reach from the humidifier drain connection to the floor drain.
  • Page 5: Installing The Humidifier

    HE360 HUMIDIFIER AND INSTALLATION KIT ALTERNATE LOCATION RETURN RETURN 6 in. (152 mm) 15 in. (381 mm) MINIMUM MINIMUM BEST LOCATION RETURN AIR DUCT M12831 Fig. 2. Selecting duct location for humidistat. Locating Closest 120V Electrical Outlet • Select location with access to an outlet. If not available, contact an electrician to have one installed.
  • Page 6 HE360 HUMIDIFIER AND INSTALLATION KIT FEED TUBE NOZZLE WATER DISTRIBUTION TRAY HUMIDIFIER PAD ASSEMBLY HUMIDIFIER HOUSING COVER THUMB ASSEMBLY SCREW M12809 Fig. 3. Disassembling humidifier. 7. Position the securing clips as shown in Fig. 4. CLIP CLIP M12813 Fig. 4. Position securing clips.
  • Page 7: Level

    HE360 HUMIDIFIER AND INSTALLATION KIT DUCT LEVEL SHEET METAL SCREWS (4) OPENING TO AIR DUCT PLASTIC TABS (2) M20204 DRAIN TUBING Fig. 5. Installing humidifier on duct. 11. Reinstall the humidifier pad assembly in the humidifier housing. IMPORTANT Be sure to reconnect the water feed tube and ensure that the tube is not pinched or kinked.
  • Page 8 HE360 HUMIDIFIER AND INSTALLATION KIT CAUTION Chemical Hazard. Can cause personal injury or equipment damage. Do not use any line connected to an air conditioner. Do not use gas line. 2. Use the self-piercing saddle valve (included) to tap into the water supply line at the location selected.
  • Page 9: Brass Inserts

    HE360 HUMIDIFIER AND INSTALLATION KIT NOTE: Do not over-tighten the compression nut. Moderate tightness prevents leak- ing. e. Repeat steps a. through d. for solenoid valve fitting. Secure tubing with clamps provided. BRASS COMPRESSION NUT PLASTIC COMPRESSION RING BRASS INSERT M20176 Fig.
  • Page 10 HE360 HUMIDIFIER AND INSTALLATION KIT 1. Disconnect power from the humidifier before installing. 2. Mount the switch vertically with pressure connectors facing down, using pro- vided self-tapping screws to secure the switch to the duct. M27300 Fig. 9. Pressure switch—oriented vertically.
  • Page 11: Rubber Gasket

    HE360 HUMIDIFIER AND INSTALLATION KIT 3. The return duct is recommended, however the switch can also be mounted to the supply duct. 4. Cut a 3/4-in. diameter hole in the duct within 10 feet of the switch to ensure the provided tubing reaches the pressure tap elbow.
  • Page 12: Installing The Humidistat

    HE360 HUMIDIFIER AND INSTALLATION KIT Installing the Humidistat Installing on Mounting Duct 1. Apply the template to the duct location chosen for the humidistat. Make sure the template is level before drilling the holes. 2. Refer to the template (provided with the H8908 Humidistat Installation Instructions) to drill the control assembly opening and mounting holes for the H8908.
  • Page 13 HE360 HUMIDIFIER AND INSTALLATION KIT IMPORTANT All wiring must comply with applicable local code, ordinances and regula- tions. Wire the humidifier solenoid valve, pressure switch, humidistat and transformer. See Fig. 13. HUMIDISTAT TRANSFORMER HUMIDIFIER SOLENOID VALVE AIR PRESSURE SWITCH M28974 Fig.
  • Page 14: How Your Humidifier Works

    OPERATION How Your Humidifier Works Your Honeywell humidifier uses the principle that vapor (evaporated water) is created when warm air blows over a water-soaked area. As the vapor circulates, the relative humidity rises. Your humidity control monitors the relative humidity and activates the humidifier accordingly.
  • Page 15 HE360 HUMIDIFIER AND INSTALLATION KIT Controlling Your Humidity Settings Your H8908 Humidistat controls your humidifier. • Choose the humidity control setting using the combination of relative humidity/ outdoor temperature setting scale on your humidity control dial. • Match the dial setting to the outdoor temperature to optimize the humidity level while reducing the moisture condensation on your windows.
  • Page 16: Maintaining Your Humidifier

    You can use either hard or soft water in your humidifier, but hard water mineral deposits are more difficult to clean than soft water deposits. Use the following procedure to clean your Honeywell humidifier. WARNING Serious Personal Injury Hazard.
  • Page 17 HE360 HUMIDIFIER AND INSTALLATION KIT FEED TUBE NOZZLE WATER DISTRIBUTION TRAY HUMIDIFIER PAD ASSEMBLY HUMIDIFIER HOUSING COVER THUMB ASSEMBLY SCREW M12809 Fig. 14. Cleaning your humidifier. 7. Disconnect the drain hose from the drain fitting on the bottom of the humidifier housing.
  • Page 18 HE360 HUMIDIFIER AND INSTALLATION KIT TROUBLESHOOTING YOUR HUMIDIFIER Table 3. Troubleshooting Humidifier. Problem What to look for What to do Water leakage Leaking joints. Shut off water. Tighten connections. Brass tubing inserts Verify that brass tubing inserts are used. Saddle valve leaking. Verify rubber pad is installed on saddle valve.
  • Page 19 This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer.
  • Page 20 HE360 HUMIDIFIER AND INSTALLATION KIT Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 Honeywell Limited-Honeywell Limitée 35 Dynamic Drive ® U.S. Registered Trademark Toronto, Ontario M1V 4Z9 © 2011 Honeywell International Inc. 69-2631ES—01 M.S.
  • Page 21: 69-2631Es-01

    Humidificador HE360 y kit de instalación 69-2631ES-01...
  • Page 22 Le damos la bienvenida al mundo confortable del aire humidificado. Cuando utilice su humidificador Honeywell, observará que su piel no estará tan seca, y que la garganta rasposa y los conductos nasales irritados que agravan las alergias y el asma mejorarán continuamente.
  • Page 23 HUMIDIFICADOR HE360 Y KIT DE INSTALACIÓN Tabla 1. Accesorios incluidos. Cantidad Accesorio 1 bolsa Elementos de montaje y conexión: Empalmes para cables (4) Tornillos Nº 8 para lámina de metal (18) Abrazadera para el tubo de drenaje Abrazaderas de montaje para el tubo de alimentación (6) Insertos de latón (2)
  • Page 24 • Elija la ubicación con acceso a un drenaje de piso para proporcionar la salida de la condensación del aire acondicionado y el drenaje del humidificador. • Si no existe un drenaje disponible, recomendamos que instale el tambor Honeywell para toda la casa o el humidificador de disco. Cerciórese de que los 10 pies (3 m) de tubería de drenaje sean adecuados para la conexión desde el drenaje del...
  • Page 25 HUMIDIFICADOR HE360 Y KIT DE INSTALACIÓN Para el montaje en el conducto de retorno, el humidistato debe montarse por encima del humidificador o desviador, de modo que detecte adecuadamente la humedad relativa del espacio habitable. Ubique el control, al menos, 8 in (203 mm) por encima del humidificador en el conducto de aire de retorno.
  • Page 26 HUMIDIFICADOR HE360 Y KIT DE INSTALACIÓN 2. Trace una línea nivelada en el plenum en la ubicación elegida para el humidificador. (La nivelación garantiza el desempeño óptimo del humidificador). 3. Ubique la plantilla (formulario número 69-2641 que se incluye en la caja).
  • Page 27 HUMIDIFICADOR HE360 Y KIT DE INSTALACIÓN 10. Perfore agujeros e inserte los tres tornillos para lámina de metal en la parte superior de la carcasa del humidificador. Fije la carcasa con los tres tornillos restantes. CONDUCTO NIVELADO TORNILLOS PARA LÁMINA...
  • Page 28 HUMIDIFICADOR HE360 Y KIT DE INSTALACIÓN PRECAUCIÓN Peligro de sustancias químicas. Puede causar lesiones personales o daño al equipo. No utilice ninguna tubería conectada a un equipo de aire acondicionado. No utilice tubería de gas. 2. Utilice la válvula de montura autoperforante que se incluye para insertar en la tubería de agua en la ubicación elegida.
  • Page 29 HUMIDIFICADOR HE360 Y KIT DE INSTALACIÓN d. Inserte la tubería en el acople de la válvula del solenoide y sostenga la válvula mientras aprieta la tuerca de compresión. NOTA: no apriete demasiado la tuerca de compresión. Un ajuste moderado evita fugas.
  • Page 30 HUMIDIFICADOR HE360 Y KIT DE INSTALACIÓN Instalación del interruptor de presión IMPORTANTE No instale el interruptor en un área donde la temperatura exceda la clasificación de -40 °F a 190 °F (-40 °C a 88 °C). 1. Desconecte la electricidad del humidificador antes de instalar.
  • Page 31 HUMIDIFICADOR HE360 Y KIT DE INSTALACIÓN 3. Se recomienda el conducto de retorno; sin embargo, el interruptor también puede montarse en el conducto de suministro. 4. Haga un agujero de 3/4 in (19 mm) de diámetro en el conducto a 10 pies (3 m) de distancia del interruptor para lograr que la tubería que se...
  • Page 32 HUMIDIFICADOR HE360 Y KIT DE INSTALACIÓN 8. Puede cortar la tubería para adecuar el largo de la conexión entre el codo de acople y el interruptor. También se recomienda fijar la manguera a las estructuras existentes para evitar la desconexión accidental.
  • Page 33 HUMIDIFICADOR HE360 Y KIT DE INSTALACIÓN CABLEADO PRECAUCIÓN Voltaje peligroso. Puede causar lesiones personales o daño al equipo. Desconecte el suministro eléctrico antes de instalar o prestar servicio al equipo. IMPORTANTE Todo el cableado debe cumplir con la normativa, ordenanzas y regulaciones locales pertinentes.
  • Page 34 FUNCIONAMIENTO Cómo funciona su humidificador Su humidificador Honeywell utiliza el principio de que el vapor (agua evaporada) se crea cuando el aire cálido sopla sobre un área empapada con agua. A medida que circula el vapor, la humedad relativa se eleva.
  • Page 35 Puede utilizar agua dura o blanda en su humidificador, pero los depósitos de minerales del agua dura son más difíciles de limpiar que los depósitos del agua blanda. Emplee el siguiente procedimiento para limpiar su humidificador Honeywell. 69-2631ES—01...
  • Page 36 HUMIDIFICADOR HE360 Y KIT DE INSTALACIÓN ADVERTENCIA Peligro de lesiones personales graves. Puede causar descarga eléctrica y lesiones provocadas por las piezas en movimiento. Desconecte la electricidad y corte el suministro de agua antes de retirar la cubierta. IMPORTANTE Nunca aceite ninguna pieza del humidificador.
  • Page 37 HUMIDIFICADOR HE360 Y KIT DE INSTALACIÓN 7. Desconecte la manguera de drenaje del acople de drenaje en la parte inferior de la carcasa del humidificador. 8. Limpie el acople de drenaje, si fuese necesario. 9. Doble la manguera de drenaje para aflojar los depósitos de minerales.
  • Page 38 HUMIDIFICADOR HE360 Y KIT DE INSTALACIÓN Tabla 3. Localización y solución de problemas del humidificador. No hay agua en Electricidad Verifique el cableado del circuito de control. el drenaje. Revise todas las conexiones. Humidistato Gire el humidistato hacia arriba y hacia abajo, y escuche que el contacto haga clic.
  • Page 39 HUMIDIFICADOR HE360 Y KIT DE INSTALACIÓN Tabla 3. Localización y solución de problemas del humidificador. Humedad baja El soplador del • Reinicie el interruptor de circuito o sistema de verifique si hay algún fusible quemado. calefacción no • Verifique que haya energía en el sistema está...
  • Page 40 HUMIDIFICADOR HE360 Y KIT DE INSTALACIÓN GARANTÍA LIMITADA DE UN AÑO Honeywell garantiza por el período de un (1) año a partir de la fecha de compra por parte del consumidor, que este producto, sin incluir la almohadilla del humidificador, no presentará...

Table of Contents