HP ProLiant DL360p Quickspecs page 5

Generation 8
Hide thumbs Also See for ProLiant DL360p:
Table of Contents

Advertisement

QuickSpecs
Standard Features
Expansion Slots
Expansion Slots
Expansion Slots
Expansion Slots
HP Server ROM
HP Server ROM
HP Server ROM
HP Server ROM
Storage Controller
Storage Controller
Storage Controller
Storage Controller
One of the following
depending on Model
Expansion Slots
Expansion Slots
Expansion Slots
Expansion Slots
Technology
Technology
Technology
Technology
# # # #
1
PCIe 3.0
2
PCIe 3.0
*Indicates the number of physical electrical lanes running to the connector.
NOTE:
NOTE: Two PCIe 3.0 expansion slots: (1) Half-length, full-height slot and (1) low-profile slot.
NOTE:
NOTE:
HP ROM (Read Only Memory) is now digitally signed using HP's Corporate Signing Service. This
signature is verified before the flash process starts, reducing accidental programming and preventing
malicious efforts to corrupt system ROM.
HP ROM provides for essential initialization and validation of hardware components before control is
passed to the customer-installed operating system. The ROM also provides the capability of booting from
various fixed media (HDD, CD-ROM) and removable media (USB), to continue operation to the
operating system.
HP ROM performs very early configuration of the video controller, to allow monitoring of initialization
progress via an attached monitor. If configuration or hardware errors are discovered during this early
phase of hardware initialization, suitable messages are now displayed on the connected monitor.
Additionally, these configuration or hardware errors are logged to the Integrated Management Log (IML)
to assist in diagnosis.
HP's ProLiant ROM is used to configure the following:
Processor and chipset status registers
System memory, memory map, and memory initialization
System hardware configuration (Integrated PCI devices and optional PCIe cards).
Customer-specific BIOS configuration (using the HP ROM-Based Setup Utility (RBSU).
NOTE:
NOTE:
NOTE:
NOTE: For further information, please refer to HP's RBSU (ROM based setup utility) user guide:
www.hp.com/support/rbsu.
Entry Models
Base Models
High Performance Models HP Smart Array P420i/2GB with FBWC (RAID 0/1/1+0/5/5+0)
Energy Star - Base and
Entry Models
DA - 14211
North America — Version 5 — April 19, 2012
HP ProLiant DL360p Generation 8 (Gen8)
HP ProLiant DL360p Generation 8 (Gen8)
HP ProLiant DL360p Generation 8 (Gen8)
HP ProLiant DL360p Generation 8 (Gen8)
Bus
Bus
Bus
Bus
Width*
Width*
Width*
Width*
x8
x16
HP Smart Array P420i/ZM (RAID 0/1/1+0)
HP Smart Array P420i/1GB with FBWC (RAID 0/1/1+0/5/5+0)
HP Smart Array P420i/1GB FBWC (RAID 0/1/1+0/5/5+0)
HP Smart Array P420i/ZM (RAID 0/1/1+0)
Connector
Connector
Connector
Connector
Form Factor
Form Factor
Form Factor
Form Factor
Width
Width
Width
Width
x8
Low profile slot
x16
Half-length, full-
height slot
Notes
Notes
Notes
Notes
Page 5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proliant dl360p generation 8Proliant dl360p gen8

Table of Contents