20Mf605T/17 - Philips 15MF605T/17 Service Manual

F1 lcd monitor/tv f1-15" f1-20"
Table of Contents

Advertisement

Magnavox LCD TV
84
Go to cover page
6.0 Environmental characteristics
The following sections define the interference and susceptibility condition limits
that might occur between external environment and the display device.
6.1 Susceptibility of display to external environment
6.2 Transportation tests
Standard
Drop
Test
Vibration
Test
6.3 Display disturbances from external environment
According to IEC 801-2 for ESD disturbances
7.0 Reliability
7.1 Mean Time Between Failures
2004-12-15
ISON KUO
GENERAL PRODUCT SPECIFICATION
Operating
- Temperature : 0 to 35
- Humidity
: 80% max
- Altitude
: 0-3658m
- Air pressure : 600-1100 mBAR
Storage
- Temperature : -20 to 60
- Humidity
: 95% max ( < 40
- Altitude
: 0-12192m
- Air pressure
: 300-1100 mBAR
Note: recommend at 0 to 35°C, Humidity less than 60 %
Height
Sequence
Electrical function ok
Test
Mechanical function ok
Result
No serious damage on set appearance
(room temp./-10 , humidity 70 %)
Sequence
--- PACKAGING
5~500 Hz , 0.73Gms , 30 min. for Each axis(X,Y.Z)
Test
Electrical function ok
Result
Mechanical function ok
No serious damage on set appearance
System MTBF (Excluding the LCD panel and CCFL) : 50,000 hrs
CCFL MTBF : 40,000 hrs
20" F1 TFT LCD Monitor/TV
TYPE

:20MF605T/17

BRAND : Magnavox
2004-12-15
)
ISTA-1A
61cm
1C-3E-6F (10 drops)
8639 000 16038
23
590
18

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

20mf605t/17

Table of Contents