4. X-RAY PROTECTION CIRCUIT FAILURE DIAGNOSIS PROCEDURES

X-ray protection circuit does
not work (When X - R
terminals are connected).
Check voltage at D471
cathode. (20 - 22V?)
OK
Check and repair Z801.
NG
129
Check and repair D471, R472.
Check and repair around pin
9 of FBT.