Cd Section - Sony HCD-M100 Service Manual

Sony compact component system - service manual
Table of Contents

Advertisement

CD SECTION

Note :
1.
CD Block is basically designed to operate without adjustment.
Therefore, check each item in order given.
2.
Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3.
Use an oscilloscope with more than 10 MW impedance.
4.
Clean the object lens by an applicator with neutral detergent
when the signal level is low than specified value with the
following checks.
oscilloscope
BD board
TP (FE)
TP (VC)
S Curve Check
Procedure :
1.
Press the @/1 button to turn ON the power .
2.
Open the front cover, and press the CD PLUS ONE button.
3.
Set the disc (YEDS-18) into the "PLUS ONE" slit.
4.
Close the front cover, and chuck the disc.
5.
Press the @/1 button to turn OFF the power.
6.
Connect the oscilloscope to TP (FE) of the BD board.
7.
Connect TP (ADJ) of the MAIN board and connect TP (GND)
with a lead wire.
8.
Press the @/1 button to turn ON the power.
9.
The first track will be played back automatically. When the
CHECK button is pressed, "S JI" will be displayed on the
fluorescent indicator tube, and focus search will be repeated.
10. Check the oscilloscope waveform (S-curve) is symmetrical
between A and B. And confirm peak to peak level within 1.8 ±
0.6 Vp-p.
S-curve waveform
symmetry
A
within 1.8 ± 0.6Vp-p
B
11. Turn OFF the power, and remove the lead wire connected at
step 7.
Note : • Try to measure several times to make sure than the ratio
of A : B or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the
brightness to obtain best waveform.
RF Level Check
oscilloscope
BD board
TP (RF)
TP (VC)
Procedure :
1.
Press the @/1 button to turn ON the power.
2.
Open the front cover, and press the CD PLUS ONE button.
3.
Set the disc (YEDS-18) into the "PLUS ONE" slit.
4.
Close the front cover, and chuck the disc.
5.
Press the @/1 button to turn OFF the power.
6.
Connect the oscilloscope to TP (RF) of the BD board.
7.
Connect TP (ADJ) of the MAIN board and connect TP (GND)
with a lead wire.
8.
Press the @/1 button to turn ON the power.
9.
Playback the fifth track of the disc.
10. Confirm that oscilloscope waveform is clear and check RF sig-
nal level is correct or not.
11. Turn OFF the power, and remove the lead wire connected at
step 7.
Note : A clear RF signal waveform means that the shape "◊" can be
clearly distinguished at the center of the waveform.
RF signal waveform
VOLT/DIV : 200mV
TIME/DIV : 500ns
+0.3
level : 1.8 ±
Vp-p
–0.2
E-F Balance (Traverse) Check
The procedure for this checking method differs for when a general
remote control unit is used and not used.
oscilloscope
BD board
TP (TE)
TP (VC)
When a general remote commander is used:
Press the @/1 button to turn ON the power.
1.
2.
Open the front cover, and press the CD PLUS ONE button.
3.
Set the disc (YEDS-18) into the "PLUS ONE" slit.
4.
Close the front cover, and chuck the disc.
5.
Press the @/1 button to turn OFF the power.
6.
Connect the oscilloscope to TP (TE) of the BD board.
7.
Connect TP (ADJ) of the MAIN board and connect TP (GND)
with a lead wire.
8.
Press the @/1 button to turn ON the power.
9.
Playback the fifth track of the disc.
10. Press the 3 button on the remote commander. (The tracking
servo and the sledding servo are turned OFF.)
11. Check the level B of the oscilloscope's waveform and the A
(DC voltage) of the center of the Traverse waveform.
Confirm the following :
A/B x 100 = less than ± 10%
Traverse waveform
Center of the waveform
B
A (DC voltage)
0V
level : 0.7 ± 0.3 Vp-p
12. Press the 8 button on the remote control unit. (The tracking
servo and sledding servo are turned ON.) Confirm the C (DC
voltage) is almost equal to the A (DC voltage) is step 11.
Traverse waveform
0V
Tracking servo
Tracking servo
Sled servo
Sled servo
ON
OFF
13. Turn OFF the power, and remove the lead wire connected at
step 7.
oscilloscope
BD board
TP (TE)
TP (VC)
When a general remote commander is not used:
1.
Solder lead wires to TP (DVDD) and TP (TOFF) on the BD
board severally.
2.
Connect the oscilloscope to TP (TE) of the BD board.
3.
Press the
button to turn ON the power.
@/1
4.
Open the front cover, and press the CD PLUS ONE button.
5.
Set the disc (YEDS-18) into the "PLUS ONE" slit.
6.
Close the front cover, and chuck the disc.
7.
Playback the fifth track of the disc.
8.
Short-circuit the lead wire connected at step 1. (The tracking
servo is turned OFF)
9.
Check the level B of the oscilliscope's waveform and the A
(DC voltage) of the center of the Traverse waveform.
Confirm the following :
A/B × 100 = less than ± 10%
Traverse waveform
0V
10. Disconnect the lead wire short-circuited at step 8. (The tracking
servo is turned ON.) Confirm the C (DC voltage) is almost
equal to the A (DC voltage) is step 8.
Traverse waveform
0V
Tracking servo
OFF
11. Turn OFF the power, and remove the lead wire connected at
step 1.
RF PLL Free-run Frequency Check
Procedure :
1.
Connect the frequency counter to TP (PLCK) of the BD board.
frequency counter
BD board
TP (PLCK)
2.
Press the
button to turn ON the power.
@/1
C (DC
voltage)
3.
Open the front cover, and press the CD PLUS ONE button.
4.
Set the disc (YEDS-18) into the "PLUS ONE" slit.
5.
Close the front cover, and chuck the disc.
6.
Playback the fifth track of the disc.
7.
Confirm that reading on frequency counter is 4.3218 MHz ±
30 kHz.
23
23
Adjustment Location :
[ BD BOARD ] — CONDUCTOR SIDE —
IC102
TP
(RF)
IC101
TP
(VC)
Center of the waveform
B
A (DC voltage)
[ MAIN BOARD ] — COMPONENT SIDE —
level : 0.7 ± 0.3 Vp-p
CN402
CN401
C (DC
2
8
2
16
voltage)
1
9
1
15
Tracking servo
ON
CN102
TP
CN103
(PLCK)
TP
CN101
TP
(DVDD)
(TOFF)
TP
(FE)
TP
(TE)
IC501
11
1
CN301B
12
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hcd-m300av