1-2. DISPLAY OF STANDBY/TIMER LIGHT FLASH COUNT
2 times
3 times
4 times
5 times
6 times
7 times
Diagnostic Item
+B overcurrent
+B overvoltage
V deflection stop
White balance failure
High voltage protector
Audio Protection
* One flash count is not used for self-diagnostic.
1-3. STOPPING THE STANDBY/TIMER FLASH
Turn off the power switch on the TV main unit or unplug the power cord from the outlet to stop the STANDBY/TIMER lamp from
flashing.
Lamp ON
0.3 sec.
Lamp OFF
Lamp OFF
3 sec.
0.3 sec.
Flash Count *
2 times
3 times
4 times
5 times
6 times
7 times
– 6 –
KP-FX43M31/M61/M91
KP-FX53M31/M61/M91
STANDBY/TIMER
lamp
RM-998