Ë P-IN-P ADJUSTMENT
P-IN-P Y-LEVEL Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "P01".
3. Adjust "P01" data value to obtain normal contrast
level.
P-IN-P TINT Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "P02".
3. Adjust data value to "29h".
P-IN-P COLOR Adjustment
1. Receive a good local channel.
2. Make sure the customer color control is set to center
position.
3. Enter the service mode and select the service
adjustment "P03".
4. Adjust "P03" data value to obtain normal color level.
P-IN-P Y-OFF SET Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "P04".
3. Adjust data value to "09h".
P-IN-P H-POSITION Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "P05".
3. Adjust data value to "0Ah".
P-IN-P BURST GATE PULSE (for MAIN)
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "P06".
3. Adjust data value to "00h".
P-IN-P FREERUN
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "P07".
3. Adjust data value to "0Bh".
P-IN-P TINT INPUT Adjustment
1. Receive an AV/Component input signal.
2. Enter the service mode and select the service
adjustment "P08".
3. Adjust data value to "24h".