Imaging Process Adjustment - Canon PowerShot A100 Service Manual

Canon powershot a100/a200 digital camera service manual
Hide thumbs Also See for PowerShot A100:
Table of Contents

Advertisement

3.5.3

Imaging Process Adjustment

I Tools Used
• Personal Computer
• INTERFACE CABLE IFC-300PCU
• Brightness Box (light source A)
• Compact Power Adapter CA-PS800
1
Click the "Imaging Process" button.
2
When the message on the right appears, go to 3.
3
1. Attach the ND Filter* between the Lens and
the Color Viewer.
2. Place the camera so that the lens is set against
the center part of the Color Viewer.
3. Click the "ADJUST" button.
* PowerShot A100 : ND-4
PowerShot A200 : ND-2
CHAPTER 3. REPAIR INSTRUCTION
• Color Viewer (5600° K)
• Adjustment Software
• W-10 Filter (2 pcs.)
Color Viewer
Personal
Computer
3-33
• Color Bar Chart
• ND-2 or ND-4 Filter
• C-12 Filter
ND-4 or ND-2
Filter
CAMERA
BODY
Power
Source
Stand