Honeywell Q682 User Manual page 18

Heating or cooling thermostat and wallplate or heating/cooling thermostat and subbase
Hide thumbs Also See for Q682:
Table of Contents

Advertisement

Troubleshooting (Continued)
Problem
Thermostat setting
and thermometer
reading disagree.
Timer does not run.
Check
— Level position of thermostat.
— Area around thermostat for
drafts or radiant heat.
— Calibration of thermometer.
—Thermostat connections at the
two C terminals. If no
connections, timer needs
batteries in to run.
— Batteries may not have been
installed.
— Batteries may need
replacement.
— If new batteries are installed
and timer still does not run.
Action
Reinstall thermostat wallplate or
subbase. Use a spirit level.
Thermostat should be about 5 ft
[1.5m] above floor on an inside wall.
Contact qualified service technician for
change of location.
See Thermometer Adjustment section.
3
Install as shown in Fig. 2.
Replace with two new AAA alkaline
batteries as shown in Fig. 2.
Replace thermostat.
18
(continued)
69-0643—1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

191108ajT8190a