4-7 Optical Performance Measure
1. Measure setting
2. Brightness
Criteria: 1155 ANSI Lumens(ES529/EX539)
1210 ANSI Lumens(EW539)
3. Contrast
Criteria: 1800:1(ES529/EX539)
1600:1(EW539)
4. Uniformity
Criteria: 70%
Note:The other contents please refer to common service manual 4-8
Optical Performance Measure.
- Please get into OSD menu,select "Lamp
Setting" under "Options",select"Brightness
Mode",then select "Bright" mode.
- Test equipment: video generator.
- Test signal:analog 800x600@60Hz (ES529)
analog 1024x768@60Hz (EX539)
analog 1280x800@60Hz (EW539)
ES529/EX539/EW539