6. ADJUSTMENT PROCEDURE

ALIGNMENT INSTRUCTIONS

(1) EQUIPMENT NEEDED
AM Standard Signal Generator
FM Standard Signal Generator
Oscilloscope
VTVM (AC,DC)
AM Test Loop Antenna (AM Adjustment)
FM Dummy Antenna (FM Adjustment)
Stereo Signal Generator (RDS IN : EUROPE ONLY)
Frequency Counter
Distortion Analyser
Item
Modulation
Band
AM
FM (EUR, OVC)
MONO : 40 kHz DEV.
SR5000/N1B
STERO : L=R (40 kHz), PILOT (7.5 kHz) 47.5 kHz DEV.
SR5000/K1B
RDS : STEREO + RDS (1.2 kHz) 48.7 kHz DEV.
FM (USA)
MONO : 75 kHz DEV. (100 %)
SR5000/U1B
DTEREO : L=R (67.5 kHz), PILOT (7.5 kHz)

TUNER ADJUSTMENT POINT

IMPORTANT
1.Check power-source voltage.
2.Set the function switch to band aligned.
3.Keep the signal input as low as possible to adjust accurately.
4.Modulation and modulation frequency.
Modulation freq.
30 %
400 Hz
1 kHz
1 kHz
37

(2) FM, AM TRACKING VOLTAGE ADJUSTMENTS

AM,FM DC Voltmeter : Connect to test point TP1 and GND
NO Band
Frequency
Adjust for
Adjustment
1
FM
87.50 MHz
1.6V
L7
AM
522 kHz
1.0V
L13
2
AM
520 kHz
1.0V
L13
DC EVM
UNIT
FM
TP1
AM
GND
GND
(3) AM RF ADJUSTMENTS
Signal generator : Connect to the AM Ant.
Coil through the loop antenna.
Adjust for the indication of VTVM of the wave form of scope
to be maximum.
/N1B, /K1B
Band NO
Frequency
Adjust for
Adjustment
1
612 kHz
L12,T13
Max sensitivity
AM
2
1503 kHz
Max sensitivity
CT1
3
Repeat steps 1 and 2 several times.
/U1B
Band NO
Frequency
Adjust for
Adjustment
1
610kHz
L12,T13
Max sensitivity
AM
2
1510 kHz
Max sensitivity
CT1
3
Repeat steps 1 and 2 several times.
DC EVM
FM-SG
MHz
OUT
UNIT
Choke coil
TP12
100 H
TP13
output
FM Dummy
DISTORTION
FM 75ome in
ANALYSER
(4) FM RF ADJUSTMENTS
Signal generator : Connect to FM Ant. (FM 75 ohm) through
the dummy.
Adjust for indication of VTVM of the wave form of scope to
be maximum.
Band NO
Frequency
Adjust for
Adjustment
1
100.10 MHz
L2,L5,L6,T1
Max sensitivity
FM
3
Repeat steps 1 several times.
AC EVM
OSCILLOSCOPE
AM-SG
kHz
AM LOOP antenna
OUTPUT
terminal
60cm
(5) FM MONO DISTORTION ADJUSTMENTS
Signal Generator : Connect to FM Ant. (FM 75 ohm) through
the dummy.
DC Voltmeter : Connect to TP2(+),TP3(-) through the choke
coil (100uH).
Distortion Meter : Connect to output L or R.
Band NO
Frequency
Adjust for
Adjustment
1
100.10 MHz DC Voltmeter 0V
T11
FM
2
100.10 MHz
Minimum T.H.D
T12
3
Repeat steps 1 and 2 several times.
AC EVM
OSCILLOSCOPE
FM-SG
MHz
OUT
UNIT
FM Dummy
FM 75ome in
OUTPUT