LG LS-M3021CL Service Manual page 28

Room air conditioner
Table of Contents

Advertisement

6. Wrap the insulation material around the connecting
portion.
I Overlap the connection pipe insulation material and
the indoor unit pipe insulation material. Bind them
together with vinyl tape so that there is no gap.
Plastic bands Insulation material
I Wrap the area which accommodates the rear pip-
ing housing section with vinyl tape.
Connection
pipe
Vinyl tape
(wide)
Connecting cable
Vinyl tape(narrow)
I Bundle the piping and drain hose together by
wrapping them with vinyl tape over the range with-
in which they fit into the rear piping housing sec-
tion.
Wrap with vinyl tape
Pipe
Drain hose
Indoor
unit pipe
Wrap with vinyl tape
Pipe
Vinyl tape(wide)
For right rear piping
1. Route the indoor tubing and the drain hose to the
required piping hole position.
2. Insert the piping, drain hose and the connecting
cable into the piping hole.
3. Insert the connecting cable into the indoor unit.
I Don't connect the cable to the indoor unit.
I Make a small loop with the cable for easy
connection later.
4. Tape the drain hose and the connecting cable.
• Connecting cable
- 28 -
Drain hose
Connecting cable
Drain pipe