When installing two or more appliances next to each other a spacer bar b must
be used between each one.
See "Fitting the spacer bars and support brackets".
Worktop cut-out
- two appliances
D
To calculate the cut-out width (D) required:
Add up the widths of each appliance (e.g. width A + B + C etc.) and subtract
16 mm from this figure
(i.e. 8 mm is taken off either end of the appliance run).
Number of
appliances
1
2
2
3
Installation of several appliances
5 0
0
b
C
A
Appliance width in mm Worktop cut-out in mm
288
288, 288
288, 380
288, 288, 288
Worktop cut-out
- three appliances
D
b
288 - 16 = 272
288 + 288 - 16 = 560
288 + 380 - 16 = 652
288 + 288 + 288 - 16 = 940
5 0
0
C
B
A