Panasonic KX-TG1711MEB Service Manual page 15

Dect 6.0 digital cordless phone, caller id compatible
Hide thumbs Also See for KX-TG1711MEB:
Table of Contents

Advertisement

Frequency Used Items (Base Unit)
Note:
*: When you enter the address, please refer to the table below.
Desired Number (hex)
0
1
.
.
.
9
ex.)
Items (*2)
Address
C-ID (FSK) sensitivity
01 C1~ 01
C-ID (DTMF) sensitivity
01 B7
Frequency
01 63~ 01 64
ID
00 10~ 00 14
Bell length
015D~015E 05 5F(11sec)(*1)
PULSE Dial speed
0129~012A
(10PPS -> 20PPS)
012B~012C
012D~012E 23 28(900msec)
(*1)
Bell length
PULSE Dial speed
(10PPS -> 20PPS)
(*2)
Items
C-ID (FSK) sensitivity
C-ID (DTMF) sensitivity
Frequency
ID
Bell length
Input Keys
0
1
.
.
.
9
Default Data
00 28
(3dB up)
C2
34
(3dB up)
Given value
Given value
01 77(3sec)
01 90(40msec)
00 C8(20msec)
(*3)
02 58(60msec)
01 2C(30msec)
(*3)
(*3)
30(440msec)
055F(hex) = 1375(dec) → 1375 x 8msec = 11000msec(11sec)
0190(hex) = 400(dec) → 400 x 0.1msec = 40msec
0258(hex) = 600(dec) → 600 x 0.1msec = 60msec
2328(hex) = 9000(dec) → 9000 x 0.1msec = 900msec
FSKGain_shiftgain
Foutgains:HPFilter Foutgains
Setting value of FREQ_TRIM_REG
ID
Time until it stops bell.
Desired Number (hex)
A
B
C
D
E
F
New Data
(6dB up)
When hex changes from "0028" to "00A4" or
00 A4
00 E7
"00E7", gain increases by 3dB or 6dB.
(6dB up)
When hex changes from "34" to "38" or "3C", gain
38
3C
increases by 3dB or 6dB.
-
-
Use these items in a READ-ONLY mode to confirm
the contents. Careless rewriting may cause serious
-
-
damage to the computer system.
00 FA (2sec)
This is time until bell stops ringing. (Unit:8ms)
-
This is pulse make time. (Unit:0.1ms)
-
This is pulse break time. (Unit:0.1ms)
11
-
This is inter-digit time in pulse mode.
(Unit:0.1ms)
Description
15
KX-TG1711MEB/KX-TG1712MEB/KX-TGA171MEB
Input Keys
Press and keep 1
Press and keep 2
Press and keep 3
Press and keep 4
Press and keep 5
Press and keep 6
Remarks