Monster Power PRO 3500 Owner's Manual page 15

Professional power center with clean power stage 2 v.2.1 filtering
Table of Contents

Advertisement

PRO3500_manual_Gks.qxd
11/10/2003
4:36 PM
Page 15
PRO 3500 FEATURES
NUMBERS REFER TO DRAWING ON PAGE 7
1. ON/OFF Switch: Once the PowerCenter is plugged into a properly grounded 120V outlet, operating the switch
will provide AC power to the components plugged into the PowerCenter's Switched and Switched (Timed) outlets.
Release this button to shut down components.
2. Ground OK: When this LED is On, the PowerCenter is plugged into a properly grounded 120V AC power outlet. If
the LED is Off, unplug the PowerCenter immediately. Monster Cable
is not responsible for equipment damage
®
due to improper grounding of your home's outlets.
3. Wiring Fault: This LED indicates if the Line and Neutral wires from the wall outlet to the PowerSource
are reversed. Unplug the unit immediately and consult your electrician.
4. Clean Power On: This LED indicates that the PowerCenter is providing filtered AC power
to all connected components.
5. Abnormal Voltage: When this LED is On, the PowerCenter warns of unstable power conditions (over 130 VAC
or under 90 VAC). Outside of these limits, the PowerCenter's T2 circuitry will disconnect all components from power,
until the voltage returns to normal levels.
6. Protection On: When this LED is On, Monster Power Surge Protection Circuitry is functioning properly.
If this LED is off, Monster Power Surge Protection Circuitry has malfunctioned. If the light is off, unplug
the PowerCenter immediately. See warranty information for details on how to return damaged equipment
to Monster Power (page 18).