Chapter 6. Operation Description Of Operating Se- Quence; Oven Schenatic; Operation - Sharp R-21LCF Service Manual

Light duty commercial microwave oven
Hide thumbs Also See for R-21LCF:
Table of Contents

Advertisement

CHAPTER 6.
R21LCF

OPERATION

[1] DESCRIPTION OF OPERATING SEQUENCE
The following is a description of component functions during oven operation.
1. OFF CONDITION
Closing the door activates door sensing switch and secondary inter-
lock switch. (In this condition, the monitor switch contacts are opened.)
When oven is plugged in, 120 volts A.C. is supplied to the noise filter
and the control unit (Figure O-1).
2. COOKING CONDITION
When the Light Up Dial is turned, the following operations occur:
1) The contacts of the relays are closed and components connected
to the relays are turned on as follows.
(For details, refer to Figure O-2)
RELAY
CONNECTED COMPONENTS
RY-1
oven lamp/antenna motor/fan motor
RY-2
power transformer
2) 120 volts A.C. is supplied to the primary winding of the power trans-
former and is converted to about 3.2 volts A.C. output on the fila-
ment winding, and approximately 2150 volts A.C. on the high
voltage winding.
3) The filament winding voltage heats the magnetron filament and the
H.V. winding voltage is sent to a voltage doubler circuit.
4) The microwave energy produced by the magnetron is channelled
through the waveguide into the cavity feed-box, and then into the
cavity where the food is placed to be cooked.

[2] OVEN SCHENATIC

1. Off Condition
SCHEMATIC
NOTE: CONDITION OF OVEN
1. LIGHT UP DIAL OFF.
2. DOOR CLOSED.
NOISE FILTER
AC120V
60 Hz
THERMAL
THERMAL
CUT-OUT
CUT-OUT
145ºC (MAG.)
125ºC (OVEN)
A5
CONTROL UNIT
A3
A1
DOOR SENSING
SWITCH
SECONDARY
INTERLOCK SWITCH
Figure O-1. Oven Schematic-Off Condition
Service Manual
5) Upon completion of the cooking time, the power transformer, oven
lamp, etc. are turned off, and the generation of microwave energy
is stopped. The oven will revert to the OFF condition.
6) When the door is opened during a cook cycle, monitor switch, door
sensing switch, secondary interlock switch, relay (RY2) and pri-
mary interlock relay (RY1) are activated with the following results.
The circuits to the antenna motor, the cooling fan motor, and the
high voltage components are de-energized, the oven lamp remains
on, and the digital read-out displays the time still remaining in the
cook cycle when the door was opened.
7) The monitor switch electrically monitors the operation of the sec-
ondary interlock switch and control relay (RY1) and is mechanically
associated with the door so that it will function in the following
sequence.
a) When the door opens from the closed position, the primary
interlock relay (RY1) and secondary interlock switch open their
contacts. Then the monitor switch contacts close.
b) When the door is closed from the open position, the monitor
switch contacts open first. Then the contacts of the secondary
interlock switch and door sensing switch close.
If the secondary interlock switch and primary interlock relay (RY1) fail
with the contacts closed when the door is opened, the closing of the
monitor switch contacts will form a short circuit through the monitor
fuse, secondary interlock switch, and primary interlock relay(RY1),
causing the monitor fuse to blow.
OL
FM
AM
OVEN
FAN
ANTENNA
LAMP
MOTOR
MOTOR
6 – 1
R21LCF
POWER
TRANSFORMER
CAPACITOR
1.00 μF
2300V