R21LCF
2. Follow the troubleshooting guide given below, if indicator does not light up after above check and repairs are finished.
1) Disconnect the power supply cord and then remove outer case.
2) Open the door and block it open.
3) Discharge high voltage capacitor.
4) Disconnect the leads to the primary of the power transformer.
5) Ensure that these leads remain isolated from other components and oven chassis by using insulation tape.
6) After that procedure, re-connect the power supply cord.
7) Follow the troubleshooting guide given below for repair.
STEPS
The rated AC voltage is not present between Pin No. 5 of the 3-pin connector (A)
1
and the common terminal of the relay RY1.
8) Disconnect the power supply cord and then remove outer case.
9) Open the door and block it open.
10)Discharge high voltage capacitor.
11)Reconnect all leads removed from components during testing.
12)Re-install the outer case (cabinet).
13)Reconnect the power supply cord after the outer case is installed.
14)Run the oven and check all functions.
OCCURRENCE
8 – 6
CAUSE OR CORRECTION
Check supply voltage and oven power cord.