Location; Leveling; Installation Requirements; Plumbing Connections - Vulcan-Hart SCALEBLOCKER SPS600V Installation & Operation Manual

Scaleblocker water filtration system
Hide thumbs Also See for SCALEBLOCKER SPS600V:
Table of Contents

Advertisement

LOCATION

The water filter(s) should be mounted on a sturdy support structure or wall and must be level. Do not
mount filter system directly on steamer.

LEVELING

Use a spirit level to level the top of the water filter's mounting head.

INSTALLATION REQUIREMENTS

The SPS600V or SPS620V water filter is designed to be installed in the
cold water line only. Installation of the water filter in a hot water line can
seriously damage the filter housing.
The filter must be in contact with water at all times after installation.
Installation must comply with any existing state or local plumbing codes.
Refer to the Water Parameters table, right, for recommended water quality limitations. If your local
water supply does not meet the recommendations in the Water Parameters table, Vulcan may request
that a water sample be returned for laboratory testing. After evaluation of the water test, other specific
recommendations may be made for additional filtration or water treatment to make the local water supply
meet the acceptable limits for use in steam generator equipment.
Recommended incoming flow rate for model SPS600V is 2 gallons per minute (
model SPS620V, the recommended incoming flow rate is 4 gallons per minute (
The SPS600V and SPS620V filters must be protected against freezing. Failure to do so could result
in breakage of the filter housing and water leakage.
Minimum operating temperature: 45°F (
Minimum operating pressure: 20 psig (
Minimum line pressure: 40 psig (
If filter pressure gauge is over 60 psig (
maximum of 60 psig (
equivalent) after the filter, move the pressure gauge downstream of the regulator and set the pressure
at 60 psig (
).
414 kPa
Do not use with water that is microbiologically unsafe or of unknown quality without adequate
disinfection before or after the filter.

PLUMBING CONNECTIONS

WARNING: PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITARY, SAFETY
AND PLUMBING CODES.
The filter housing on model SPS600V and model SPS620V water filters comes with
pipe threads on both the inlet and outlet sides. The inlet is on the left; outlet is on the right, after the
pressure gauge.
Connect the incoming cold water to the water filter's incoming connection on the left.
Connect the outlet from the water filter (right of the pressure gauge) to the incoming water connection
of the boiler, steam generator, steamer or combi oven. On steamers and combi ovens with two water
connections, a boiler feed line and a cold water drain line condenser, the outlet from the water filter must
be connected to the boiler feed line on the steamer or combi oven and not to the drain line condenser.
7°C
138 kPa
). Maximum line pressure: 125 psig (
276 kPa
414 kPa
). Install a water pressure reducing regulator (part number 854322 or
414 kPa
). Maximum operating temperature: 100°F (
). Maximum operating pressure: 125 psig (
), you must reduce the pressure to the boiler to a
– 4 –
W
A
T
E
R
P
A
R
A
M
E
T
E
R
p
H
6
o t
9
l A
a k
n i l
y t i
8
0
o t
1
0
0
p
C
l h
r o
n i
e
0
o t
4
p
p
H
a
d r
n
e
s s
0
o t
3
0
0
p
). For
7.6 liters per minute
15.1 liters per minute
).
38°C
862.5 kPa
).
862.5 kPa
3
/
" NPT internal
4
S
p
m
m
p
m
).
).

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scaleblocker sps620v

Table of Contents