Fujitsu PRIMERGY BX900 Configuration Manual page 38

Blade server systems, ethernet connection blade module sb6 / sb11a / sb11 ibp version
Hide thumbs Also See for PRIMERGY BX900:
Table of Contents

Advertisement

Overlapped on Uplink Set
In this example, a Port group pg_overlap is created with uplink set uplink_1. Interfaces 0/1 ~
0/12 are set to the member of this port group. Service VLAN svlan_overlap with VLAN ID
4094 is created and it is configured with uplink set uplink_1 as its external connection.
Interfaces 0/20 ~ 0/24 are assigned to be the member of this Service VLAN.
The tagged packet with VLAN ID 4094 received on uplink_1 will be forwarded to interfaces
0/20 ~ 0/24. The tagged packet with VLAN ID rather than 4094 received on uplink_1 will be
forwarded to interfaces 0/1 ~ 0/12. The untagged packet received on uplink_1 will be also
forwarded to interfaces 0/1 ~ 0/12.
(BX900-CB1)#configure
(BX900-CB1)(Config)#port-group pg_overlap uplink_1
(BX900-CB1)(Config)#interface range 0/1 – 0/12
(BX900-CB1)(if-range)#no port-group
(BX900-CB1)(if-range)#port-group pg_overlap
(BX900-CB1)(if-range)#exit
(BX900-CB1)(Config)#svc-vlan svlan_overlap 4094 uplink_1
(BX900-CB1)(Config)#interface range 0/20 – 0/24
(BX900-CB1)(if-range)#svc-vlan svlan_overlap
(BX900-CB1)(if-range)#exit
(BX900-CB1)(Config)#exit
(BX900-CB1)#show port-group pg_overlap
Port Group Name Internal Ports
-------------------------- -------------------- ------------------------ ----------------------
pg_overlap
BX900-CB1/0/1 uplink_1
BX900-CB1/0/2
BX900-CB1/0/3
BX900-CB1/0/4
BX900-CB1/0/5
BX900-CB1/0/6
BX900-CB1/0/7
BX900-CB1/0/8
BX900-CB1/0/9
BX900-CB1/0/10
BX900-CB1/0/11
BX900-CB1/0/12
Uplink Set Name External Ports
BX900-CB1/0/41
BX900-CB1/0/42