4-6 Run In Test

- Temperature: 2�°C~35°C
- Circumstance brightness: Normal environment
- Screen size: No concern
- Display mode: ECO mode
-
After repairing each unit, it should be Run-in (refer to the below table).
Symptom
Normal repair
NFF
Auto shut down
- Get into Burn-In Mode
* Cycle setting is based on the defect symptoms. ie: If it is NFF, the run-in time
is 4 hours. You have to set the LE� on for 60min. and LE� off for 15 min for
2 cycles.
Note: Please make sure that the hot exhaust airflows from projectors can flow
towards the aisle.
Press "Up"->"Home"->"Down"->"Zoom" of remote controller
Choose Burn In Test > enter
Lamp On (Min)
Lamp Off (Min)
Set Burning cycle
After setting up the time, choose ''Start Burn In Mode'' and press "O" button of remote controller.
Run-in Time
2 hours
4 hours
� hours
Press right key to adjust the time (�0)
Press right key to adjust the time (15)
Press right key to adjust the cycle