Haier HSM18HEKC03/R2 Service Manual page 59

Ek series wall mounted type air conditioner
Table of Contents

Advertisement

Turn off power supply and
rotate fan by hand
Does fan rotate
smoothly?
Yes
Turn power ON and operate fan
Does it rotate?
Yes
Stop fan motor
Is rotation number
command pulse
generated?
Replace indoor fan motor
PCB
HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM
NO
No
Y
No
Replace fan motor
Turn off power supply and disconnect fan
motor connector,then turn power ON
Check output of fan motor connector
I s m o t o r p o w e r
voltage DC310V
Yes
Is motor control power
voltageDC15Vgenerat
Yes
Is rotation number
commamd voltage
DC1 6V
No
Replace indoor unit
PCB
57
Service Diagnosis
NO
Replace indoor unit
PCB
NO
Replace indoor
unit PCB
Yes
Replace fan motor