The exact placement of the components will vary by installation. Although shown beneath a
sink, it may be installed in a basement, crawl space, or in an adjacent cabinet. Regardless of
where the system is installed, the flow sequence described by (Figure 1) must be observed.
The Aqua-Cleer
/Good Water Machine
®
near a sink for easy access to cold water and drain lines. Lengths of 1/4-inch and 3/8­
inch OD plastic tubing will be required to make this installation. A length of Culligan
tubing is required to install the air gap siphon break.
Evaluate the installation site to determine the easiest path for the plumbing to follow. Take
care to make the installation as neat as possible.
Aqua-Cleer
Faucet
Monitor
Sensor
Monitor
Ball Valve
Tank
Notice: Install the drain line so that it runs downward with no loops or low spots.
Otherwise the unit will overflow at the air gap siphon break built into the faucet, or make
irritating gurgling sounds. The concentrate line that leads to the faucet should be installed
in a straight vertical path to avoid making a gurgling noise.
drinking water system is designed to be mounted
®
Drain
Cold Water
Supply
Tubing From Faucet
Air Gap - 3/8" Tubing
Post
Filter
1/4" Tubing
to Faucet
Air Gap
3/8" Tubing
to Faucet
Product
Port
3/8" Tubing to Faucet Product Port
Figure 1
drain
®
Feed Line
1/4" Tubing
AC-30
Manifold
Installation
7