Test Mode; General Description; Starting Test Mode; Syscon Diagnosis - Sony DVP-NS305 Service Manual

Cd/dvd player with remote rmt-d141a/d142a/d142o/d142p
Hide thumbs Also See for DVP-NS305:
Table of Contents

Advertisement

6-1. GENERAL DESCRIPTION

The Test Mode allows you to make diagnosis and adjustment eas-
ily using the remote commander and monitor TV. The instructions,
diagnostic results, etc. are given on the on-screen display (OSD).

6-2. STARTING TEST MODE

Press the [TITLE], [CLEAR], [POWER] keys on the remote com-
mander in this order with the power of main unit in OFF status,
and the Test Mode starts, then "DIAG START" will be displayed
on the fluorescent display tube and the menu shown below will be
displayed on the TV screen. At the bottom of menu screen, the
model name and revision number are displayed. Last Off at the
lower right of screen indicates the information code concerning
the last power off. To execute each function, select the desired
menu and press its number on the remote commander. To exit from
the Test Mode, press the [POWER] key.
Test Mode Menu

0. Syscon Diagnosis

1. Drive Auto Adjustment
2. Drive Manual Operation
3. Mecha Aging
4. Emargency Hisory
5. Version Information
6. Video Level Adjustment
Exit: Power Key
_
Model
: DPX-6xxxx
Revision : x.xxx
Power Off Information Code List
00: Primary Power Off
01: Power Off Request from SYSTEM CONTROL
02: Power Off by Emergency Power Off Command from
SYSTEM CONTROL
(if information is sent from SYSTEM CONTROL)
03: IF CON Judged that SYSTEM CONTROL is Faulty
04: Power Off from Diagnosis Mode of IF CON
05: Forced Power Off by the User
06: Power Off by Power Supply Voltage Monitor
SECTION 6

TEST MODE

Last Off: xx
DVP-NS305/NS310/NS315/NS405/NS410/NS415
6-3. SYSCON DIAGNOSIS
The same contents as board detail check by serial interface can be
checked from the remote commander. On the Test Mode Menu
screen, press [0] key on the remote commander, and the following
check menu will be displayed.
### Syscon Diagnosis ###
0. Quit
1. All
2. Version
3. Peripheral
4. Servo
5. Supply
6. AV Decoder
7. Video
8. Audio
_
0. (Quit)
Quit the Syscon Diagnosis and return to the Test Mode Menu.
1. (All items continuous check)
This menu checks all diagnostic items continuously. Normally, all
items are checked successively one after another automatically
unless an error is found, but at a certain item that requires judg-
ment through a visual check to the result, the following screen is
displayed for the key entry.
### Syscon Diagnosis ###
Diag All Check
No. 2 Version
2-3. ROM Check Sum
Check Sum = 2005
Press NEXT Key to Continue
Press PREV key to Repeat
_
For the ROM Check, the check sum calculated by the Syscon is
output, and therefore you must compare it with the specified value
for confirmation.
Following the message, press > key to go to the next item, or
. key to repeat the same check again.
6-1
Check Menu

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents