Problem
Rocker Switch (power On/Off) is ON,
but the unit does not heat and the
light on the Rocker Switch is OFF.
Unit overheats or overcooks (water
boils).
Unit under cooks the corn.
Rocker Switch (power On/Off) is ON,
the unit does not heat, but the light
on the Rocker Switch is ON.
P/N 1010634 Rev. I 03/06

TROUBLESHOOTING

WARNING
Possible Cause
The power cord is not correctly
plugged in.
Circuit Breaker tripped.
Damaged Power Cord.
Loose, burnt, or broken wires in
circuit.
Inoperable Rocker Switch.
Safety Interlock Switch not engaged. Reposition the Head Assembly to
Inoperable Thermostat.
Water level is too low.
Inoperable Thermostat.
Inoperable Heating Element
Inoperable Thermostat.
Loose, burnt, or broken wires in
circuit.
9
CORN COOKER
Corrective Action
Plug power Cord into appropriate
outlet.
Reset the Circuit Breaker.
Replace Power Cord.
Tighten wires and replace if burned
or charred.
Replace Rocker Switch.
engage the Safety Interlock Switch
according to the operating instruc-
tions in this manual..
Replace the Thermostat
Add water so that the corn is com-
pletely covered.
Replace the Thermostat.
Replace the Heating Element.
Replace the Thermostat.
Replace wires.