USING THE POWER USAGE
METER
See Figure 1.
The power usage meter calculates the cost of power
usage by most electronic devices which plug into
OPERATOR'S MANUAL
a 120 volt AC outlet.
POWER USAGE METER
Cost is determined by the rate per Kilowatt hour
E49CM01
(kWh) charged by your local electric company. Call
your electric company for rates, or check your most
recent statement.
IMPORTANT SAFETY
NOTE: The cost of operation is only calculated after
INSTRUCTIONS
the rate per kilowatt hour is programmed.
This product displays Amps, Kilowatt Hours, Watts,
cost of operation, and the total price for the time
WARNING!
period the device was connected.
R E A d
A N d
U N d E R S TA N d
A L L
 Before first use, remove the plastic strip from
the battery compartment on the back of unit.
INSTRUCTIONS. Failure to follow all
instructions listed below may result in electric
 Press and hold the Enter button
shock, fire and/or serious injury.
the time display flashes.
• The default setting is a 12 hour clock.
 This product is for indoor use only.
 do not get the product wet. Do not use if
 To set hours and minutes, press the Clock/timer
button
this product is exposed to moisture.
 do not disassemble. This product has no
 Press Enter button (C) again to set the price
user-serviceable parts.
per kilowatt hour (max. 0.99). Press the Clock/
 As with all electrical devices, use caution
timer and Center buttons (A) or (B) to change
when plugging and unplugging this unit
the amount in cents.
into an outlet or plugging/unplugging other
 When you have input the time and price per
devices into this unit. Do not force this unit
kilowatt hour, press and hold the Enter button
into an outlet. Do not force plugs into this
(C) until the display stops flashing.
outlet.
 Plug the power usage meter into a standard,
 If required, use only UL/ETL approved
grounded wall outlet or UL/ETL approved,
extension cords with this product.
grounded 15 Amp capable extension cord.
 If this unit is used in a manner not specified
 Plug the device you wish to monitor into the
by the manufacturer, the protection
power usage meter.
provided by this equipment may be
impaired.
 When the device is plugged into the power
 do not overload the tool. It must be used
usage meter, it will begin displaying power used
for powering devices less than the product
in Watts. This is the default setting.
rating.
• To toggle the display between Kilowatt hours,
 For use in grounded outlets only. Do
Amps, and Watts, press the Center button
not remove grounding prong from back of
(B).
product.
• Press
 Operate this product using only the
• Press
AC power type listed in the product
time the device has been connected to the
specifications.
meter.
 Two- or three-prong plugs may be used
The display shows minutes from 1-59, then
with this product. Do not force a polarized
shows the time in hours. At 24 hours, the meter
plug (one prong larger than the other) into this
switches to time displayed in days.
product. Flip plug over and retry.
 Save these instructions. Refer to them
frequently and use them to instruct others
Fig. 1
who may use this product. If you loan
someone this product, loan them these
instructions also.
SPECIFICATIONS
A
B
Ratings:
0.2 to 15 Amps max or 24 to 1800 watts max.
D
@ 100-120V AC (50-60Hz)
C
display Auto Off: 2 minutes
Input: 120V AC @60Hz
Output: 15 Amps Max 120V AC @60Hz
Operating Temperature:
32º to 104ºF (0º to 40 Cº)
Operating Humidity:
20% to 80% Relative Humidity
Operating Altitude:
Up to 6500 ft. (2000m)
A - Clock/timer button
Battery Requirement:
(Bouton « Clock/timer » (Horloge/chronomètre),
(2) LR44 Button Cells
Botón Reloj/cronómetro)
Transient Voltage:1500V
B - Center button (Bouton « Center » [Centre], Botón
degree of Protection:
Centro)
IP20 (Protected against solid objects up to 12
C - Enter button (Bouton « Enter » [Entrée], Botón
mm)
Entrar)
D - Overload indicator (Indicateur de surcharge,
Pollution degree: 2
Indicador de sobrecarga)
Grounding:
E - LCD display (Afficheur ACL, Pantalla de LCD)
Measurement Category: CAT III
OPERATION
OPERATION
 To display the cost per kilowatt hour, press the
Enter button
• To toggle between Cost Per Day, Cost Per
Week, Cost Per Month, Cost Per Year, and
Total Cost calculated so far, press the Center
(B).
button
 The meter will continue to calculate cost until
the device is unplugged. The information on the
display will remain in memory until the meter is
reset.
 To reset the power usage meter, press the Clock/
timer and Enter buttons (A) and (C) at the same
time, until the display shows all zeros.
NOTE: If you do not reset the meter to clear the
memory, it will retain the most recent reading
and add it to the next one.
 The meter goes into Automatic Off mode after
two minutes of inactivity. Pressing any button
(C) until
will bring the display back up.
OVERLOAd WARNING
If the electrical current going through the power
usage meter exceeds 15 Amps, the overload
(A) or Center button
(B).
indicator light (D) will come on. If this occurs,
the power usage meter should not be used,
and the device you are attempting to measure
should be powered down and disconnected
from the meter.
REPLACING THE BATTERIES
See Figure 2.
The power usage meter uses two (2) LR44 button
cell batteries to retain readings in memory.
Estimated battery life is 4-6 months.
To replace the batteries:
 Push on the two latches of the battery cover
to remove it.
 Remove the depleted batteries.
 Install two new batteries as shown and push
the cover back into place until it clicks to
close.
 Reset the unit as previously instructed in Using
the Power Usage Meter.
to change to a 24-hour clock.
CLEANING
again to change to the duration of
If the unit becomes dirty or dusty, unplug it from
outlet. Unplug any attached devices. Wipe outside
of product with a dry or lightly dampened rag only.
Allow to dry completely prior to use. Do not use
spray cleaners.
Fig. 2
E
06:42
pm
$
19.85
WARRANTY
LIMITEd TWO YEAR WARRANTY ANd 30 dAY
(C).
EXCHANGE POLICY
30-dAY EXCHANGE POLICY: During the first 30
days after date of purchasing this product, you
may either request service under this warranty
or you may exchange it by returning it with proof
of purchase and all original equipment packaged
with the original product to the dealer from which
it was purchased. The replacement product will be
covered by the limited warranty for the balance of
the two year period from the date of the original
purchase.
LIMITEd TWO YEAR WARRANTY. This product
is warranted against all defects in workmanship or
materials for a period of two years from the date
of purchase. The warranty on any accessories for
this product, excluding batteries, is limited to 90
days from the date the accessory is purchased. To
obtain warranty service, call Customer Service at
1-800-525-2579 for warranty return instructions.
The product must be properly packaged and
returned with all equipment that was included
with the original product. When you request
warranty service, you must also present proof
of purchase documentation, which includes the
date of purchase (for example, a receipt or a bill
of sale). Defective products returned within the
warranty period will be repaired or replaced, at
our option, free of charge, within ninety (90) days
or less. The cost of shipping the product to us
is your responsibility. This warranty only covers
defects arising under normal usage and does
not cover any malfunction, failure or defects
resulting from misuse, abuse, neglect, alteration,
modification or unauthorized repairs. It applies only
to the original purchaser at retail, and may not be
transferred. One World Technologies, Inc. makes
no warranties, representations or promises as to
the quality or performance of this product other
than those specifically stated in this warranty.
Any implied warranties granted under state law,
including warranties of merchantability or fitness for
a particular purpose, are limited to two years from
the date of purchase. One World Technologies, Inc.
is not responsible for direct, indirect, or incidental
damages Some states do not allow limitations
on how long an implied warranty lasts, or the
exclusion or limitation of incidental or consequential
damages, so the above limitations and exclusions
may not apply to you. This warranty gives you
specific legal rights, and you may also have other
rights which vary from state to state.
ONE WORLd TECHNOLOGIES, INC.
1428 Pearman Dairy Road, Anderson, SC 29625
Phone 1-800-525-2579
www.ryobitools.com
C
US
3189400
Ryobi
is a registered trademark of Ryobi Limited used under
®
license.
Français
MANUEL d'UTILISATION
dISPOSITIF dE CALCUL
Puissance :
0,2 à 15 A maximum ou 24 à 1 800 W
dE LA CONSOMMATION
maximum, 100 à 120 V c.a. (50 à 60 Hz)
d'ÉLECTRICITÉ
Arrêt automatique de l'affichage :
E49CM01
2 min.
Entrée : 120 V AC @60Hz
Sortie :15 Amps Max 120V AC @60Hz
INSTRUCTIONS
Température de service :
IMPORTANTES
32º to 104ºF (0º to 40 Cº)
CONCERNANT LA SÉCURITÉ
Humidité d'exploitation :
20% - 80% d'humidité
Altitude d'exploitation:
jusqu'à 6500 ft. (2000m)
AVERTISSEMENT !
Pile requise : deux (2) piles boutons LR44
Surtension : 1 500 V
LIRE ET VEILLER À BIEN COMPRENdRE
Niveau de protection :
TOUTES LES INSTRUCTIONS. Le non-
IP20 (protection contre les objets solides
respect de toutes les instructions ci-dessous
mesurant jusqu'à 12 mm);
peut entraîner un choc électrique, un incendie
Niveau de pollution : 2
et/ou des blessures graves.
Mise à la terre :
Catégorie de mesure : CAT III
 Ce produit est conçu pour être utilisé
uniquement à l'intérieur.
 Ne pas mouiller le produit. Ne pas utiliser le
produit s'il est exposé à l'humidité.
 Ne pas désassembler le produit. Aucune
UTILISATION dE L'APPAREIL dE
de ses pièces ne peut être réparée par
l'utilisateur.
MESURE dE LA CONSOMMATION
 Comme c'est le cas avec tous les dispositifs
d'ÉLECTRICITÉ
électriques, agir avec précaution au
Voir la figure 1.
moment de brancher l'unité dans une
L'instrument de mesure de la consommation
prise et de l'en débrancher ou de brancher
d'électricité calcule le coût de la consommation
d'autres dispositifs dans cette unité et de
électrique de la plupart des dispositifs électriques
les en débrancher. Ne pas brancher de force
qui se branchent dans une prise de 120 V c.a.
l'unité dans une prise. Ne pas forcer les fiches
Le coût est déterminé selon le tarif par
à s'insérer dans cette prise.
kilowattheure (kWh) facturé par la compagnie
 Au besoin, utiliser uniquement des cordons
d'électricité locale. Communiquez avec votre
prolongateurs approuvés par Underwriters
compagnie d'électricité afin de connaître ses
Laboratories, Inc. (UL) et Electrical Testing
tarifs ou vérifiez votre relevé de compte le plus
Laboratories (ETL) avec ce produit.
récent.
 Si cette unité est utilisée d'une façon non
NOTE : Le coût d'exploitation est uniquement
conforme aux directives du fabricant, la
calculé une fois que le tarif par kWh a été saisi.
protection fournie par cet équipement peut
être détériorée.
Ce produit affiche les ampères, les kilowatt heures,
les watts, le coût d'exploitation ainsi que le coût
 Ne pas surcharger l'outil. Il doit être utilisé
total pour la période au cours de laquelle l'appareil
pour alimenter des dispositifs dotés d'une
a été branché.
puissance inférieure à la sienne.
 Avant la première utilisation, retirer la bande
 Compatible uniquement avec des prises
mises à la terre. Ne pas retirer la branche de
de plastique du compartiment des piles situé
à l'arrière de l'unité.
mise à la terre située au dos du produit.
 Appuyer sur le bouton « Enter » (Entrée)
 Utiliser ce produit uniquement avec le type
(C) et le tenir enfoncé jusqu'à ce que l'heure
d'alimentation c.a. mentionnée dans les
clignote.
spécifications du produit.
 Le réglage par défaut est fixé pour un cycle de
 Il est possible d'utiliser des fiches à deux
12 heures.
ou à trois branches avec ce produit. Ne
 Pour régler les heures et les minutes, appuyer sur
pas insérer de force une fiche polarisée
le bouton « Clock/timer » (Horloge/chronomètre)
(une branche plus grande que l'autre) dans
(A) ou sur le bouton « Center » (Centre)
le produit. Retourner la fiche et essayer de
(B).
nouveau.
 Appuyer sur le bouton « Enter » (Entrée) (C)
 Conserver ces instructions. Les consulter
pour ajuster le prix par kWh. Appuyer sur les
fréquemment et les utiliser pour instruire
boutons « Clock/timer » et « Center » (A) ou (B)
d'autres utilisateurs. Si cet outil est prêté, il
pour modifier le montant en cent.
doit être accompagné de ces instructions.
 Une fois que le temps et le prix par kWh ont été
saisis, appuyer sur le bouton « Enter » (Entrée)
(C) et le tenir enfoncé jusqu'à ce que l'afficheur
cesse de clignoter.
 Brancher l'appareil de mesure de la
consommation d'électricité dans une prise
murale standard mise à la terre, ou le relier au
moyen d'un cordon prolongateur mis à la terre
de 15 A approuvé par UL et ETL.
 Brancher le dispositif qui doit être évalué dans
l'appareil de mesure de la consommation
d'électricité.
FICHE TECHNIQUE
UTILISATION

Advertisement

loading

Summary of Contents for Ryobi E49CM01

  • Page 1 3189400 display Auto Off: 2 minutes saisis, appuyer sur le bouton « Enter » (Entrée) Ryobi is a registered trademark of Ryobi Limited used under ® (C) et le tenir enfoncé jusqu’à ce que l’afficheur Input: 120V AC @60Hz license.
  • Page 2 LIMPIEZA Si l’unité est sale ou poussiéreuse, la débrancher Botón Reloj/cronómetro) RYOBI es una marca comercial registrada de Ryobi Limited y es 3189400 ® de la prise. Débrancher tous les dispositifs fixés sur B - Center button (Bouton « Center » [Centre], Botón empleada mediante autorización.