Download Print this page
Ryobi EMTP006 Specification

Ryobi EMTP006 Specification

Electronic

Advertisement

Quick Links

EMTP006
ELECTRONIC
MeasureTech Plus™
MeasureTech Plus™
NOTE: This equipment has been tested and found to
comply with the limits for an ultrasonic equipment,
LCD
pursuant to Part 18 of the FCC Rules. These limits
are designed to provide reasonable protection against
harmful interference in a residential installation. This
equipment generates, uses and can radiate radio
READ
frequency energy and, if not installed and used in
KEY
accordance with the instructions, may cause harmful
ADDITION KEY
interference to radio communications.
ON/OFF
However, there is no guarantee that interference will
KEY
not occur in a particular installation. If this equipment
does cause harmful interference to radio or television
MULTIPLYING
reception, which can be determined by turning the
KEY
equipment off and on, the user is encouraged to
try to correct the interference by one or more of the
following measures:
SONIC
LASER
APERTURE
APERTURE
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and
receiver.
Connect the equipment into an outlet on a
circuit different from that to which the receiver is
connected.
RYOBI TECHNOLOGIES INC.
1428 Pearman Dairy Road, Anderson, SC 29625
Consult the dealer or an experienced radio/TV
www.ryobitools.com
technician for help.
Telephone: 1-800-525-2579
• Press "Read" or side yellow "On/Off" button on
the unit, if LCD screen lights up the power is on.
CAUTION
Avoid direct
Stud Sensor:
ex posure to the beam
. Read
• Up to 1-1/2 in. deep stud detection.
instructions in manual
Sonic Tape:
The Ryobi Electronic
MeasureTech Plus™
is
• Instant measurement.
intended for fast convenient distance measurement
• Dynamic measurement capability.
and for locating wood and metal studs behind walls,
• Select measurement unit - ft. in./m
floors and ceilings.
• Computation of area and volume.
For damage caused by usage other than intended,
• Addition of distances.
the user is responsible.
WARRANTY
This product is a consumable item. Therefore it is
warranted against defective parts and labor only and
not misuse or deterioration of the product through
normal wear and tear for a period of 2 years from date of
purchase.
983000-347
12-03
CALIBRATION AND SCANNING IN
EMTP006
MeasureTech Plus™
ELECTRONIC
• Position the unit against the wall.
• Press and hold the "ON/OFF" button on side of
unit. Hold the unit in still position until calibration is
complete (approximately 3 seconds). A single beep
will be generated and "ON" will be shown on the
LCD after calibration is completed.
• Slowly slide the unit horizontally across the wall,
right or left. As you begin to approach the stud, the
bars on the LCD will light up.
• When the word "EDGE" flashes and a continuous
beep is heard, mark location as the first edge.
• Continue scanning beyond the marked spot until
the word "EDGE" disappears on screen. Slide unit in
reverse direction to locate the other stud edge.
• Mark this second spot. The middle of the 2 spots is
the stud center.
NOTE: Because of the powerful scanning capability
of this tool, be sure to mark the two edges of the
stud. The two marks may indicate wider than actual
stud width, but center of stud will be between the
two marks.
MEASUREMENT PROCEDURES
• The unit functions as a distance
measurer with the top edge as
the measurement base, and is
to be held upside down.
The LCD will automatically
adapt to this orientation
and show reading accordingly.
• Select the measurement unit.
TURNING ON THE UNIT
• Point the bottom of the unit perpendicular to the
target. The laser will show where the unit is pointing
and is "ON" only while reading is being taken.
• Caution: Do not stare directly at the laser beam.
Hold the unit above or below eye level.
FEATURES
• Press the "READ" button to take the measurement.
• Hold
the
"READ"
measurement.
1-1/2 in.
CALCULATION - ADDITION
ON/OFF
1). Take the first reading.
2). Press the " + " button.
3). Take the second reading.
4). Press the " + " to get the result of length
addition
5). Repeat step one and two for further additions.
6). The result of the addition is shown at the upper
row of the LCD.
7). The 1-digit counter records the number of
readings added. It's maximum value is 9 and
larger number will be displayed as "-".
CALCULATION - MULTIPLICATION
1). Take the first reading.
2). Press the " x " button.
3). Take the second reading.
4). Press the " x " to get the result of square
measurement (sq. ft / sq. m)
5). Take the third readings.
6). Press the " x " to get the result of cubic
measurement (cu. ft / cu. m)
CHANGING MEASUREMENT
Press the " + " and the " x " buttons simultaneously
to change measurement unit from ft. to m or vise
versa.
HINTS
• Any large obstacle found within ± 5 degrees of
the viewing angle of the unit might be regarded
as the target.
• Hard surfaces usually give more accurate
results.
• To measure small, irregular or soft objects, place
a piece of cardboard on front of the object.
• The unit cannot measure through glass.
INSTALLING THE BATTERY
Measurement
• Slide the door off the back of the unit. Attach
Base
a 9V battery to the connector. Place battery in
compartment and reinstall door.
• Alkaline Battery life is approximately 20 hours.
• The battery should be replaced when battery
Target
indicator reads low charge.
button
for
continuous
� ����
WORKING WITH DIFFERENT MATERIALS
OPERATING NOTES
Stud Sensor - Depending on the proximity of
The MeasureTech Plus™ is designed for use on dry
electrical wiring or pipes to the wall surface, the
interior walls only. Three factors can affect sensing
MeasureTech Plus™ may detect them in the same
depth: Thickness, density and moisture content.
manner as studs. Caution should always be used
The MeasureTech Plus™ is not designed to
when nailing, cutting of drilling in walls, floors and
penetrate materials with inconsistent density such as:
• Ceramic floor tile
ceilings that may contain these items.
• Carpeting and padding
To avoid electrical, plumbing, etc., remember that
• Wallpaper with metallic fibers
studs or joists are normally spaced 16 in. (406 mm)
or 24 in. (610 mm) apart and are 1-1/2 in. (38 mm) in
• Freshly painted walls , not completely dry.
width. Anything closer together or a different width
• Lath and plaster
may not be a stud, joist or firebreak. Always turn off
the power when working near electrical wires.
SPECIFICATION OF PRODUCT
Sonic Tape - The use of this tool other than specified
Operating Temperature: 32°F to 104°F
may cause hazardous radiation exposure. The
Storage Temperature: -4°F to 150°F
emission power of the laser beam is less than 5mW
Distance Range: from 2 ft. to 50 ft.
Class IIIA (US version) . User must follow the below
Stud Sensor: ± 1/2" accuracy of center
warnings to avoid injury:
location behind drywall up to 1-1/2" thick.
When the laser beam is on, do not stare directly at
Sonic Tape: Distance range from 2ft. to 50ft.
it. The laser is used for locating a target only. Please
Accuracy: D ± (D x 0.5% + 1 least significant
do not point the laser into the eyes of others.
digit) where D is the actual physical distance.
The unit should not be positioned at eye level or
e.g. D = 20 ft., reading = 20 ft. ± 3 in.
operated near a reflective surface so as to avoid
Computation range of addition: 9999'11"
(999m)
beaming into the eyes of others accidentally.
Situations
Possible Causes
• No studs in that area.
No indications.
• Move several inches to the left or right and start again.
• You accidently calibrated over a stud.
• Calibration on wall of high density such
• Move several inches to the left or tight and start again.
as a wet painted wall, concrete, etc.
• On rough surfaces, place a piece of cardboard on the
• Unit not flat against wall.
LCD display
wall, so that the unit will slide smoothly when scaning.
• Unit was rocked or lifted during
• Always hold MeasureTech Plus™ parallel to stud or
"CAL FAILS"
calibration.
joist and move across it.
• Studs are normally spaced 16 in. (406mm) or 24 in.
• Detect other objects besides studs.
(610mm) apart and are 1-1/2 in. (38mm) wide, beware
• Electrical wiring and metal/plastic
of anything closer together or of a different width.
pipes may be near or touching back
Indications in too
• On rough surfaces, place a piece of cardboard on the
surface of wall
many places.
wall, so that the unit will slide smoothly when scaning.
• Battery runs out of power
• Replace with new battery
• Measured distance is <2' (0.6m) or
Inaccurate
• Make sure measured distance is within range.
> 50' (15m)
readings of
• Remove the ultrasonic source and try again.
• Another ultrasonic source is nearby.
distance
• Measured distance is<2' (0.6m) or
• Make sure measured distance is within range.
LCD displays
> 50' (15m)
• Place a piece of cardboard in front of target.
"Err"
• The target is not a good ultrasonic
• Make sure computation is within range.
reflector. (e.g. thick carpet, irregular
• Hold unit perpendicular to target and start again.
wall paper, etc.)
• The unit points to the target obliquely.
• Computation is out of the specified
range.
WARNING: To avoid risk of eye injury, do not stare directly into beam. Never point the beam into anyone's
eyes. Do not permit children to use this device. It is not a toy. To avoid risk of electric shock, ALWAYS turn power
off when working near electric wires. Avoid nailing, cutting or drilling in walls where electrical or plumbing may be
present.
Solutions

Advertisement

loading

This manual is also suitable for:

Measuretech plus emtp006