Download Print this page

Program Menus - Wilbur Curtis Company D60GT User Manual

Thermal carafe brewer

Advertisement

Y Y Y Y Y our Curtis
our Curtis
our Curtis
our Curtis ADS System is F
ADS System is F
ADS System is Factor
ADS System is F
our Curtis
ADS System is F
After connection to water and power; the rear toggle switch must be on. You will hear a beep sound, indicating power is available to the controller.
CURTIS
The control displays
Water will fill the tank (approximately 2-3 minutes depending on water flow rate). When the proper level is reached
screen. It takes approximately 20 minutes to reach setpoint temperature of 200°F.
CURTIS
Control will display
READY TO BREW
T T T T T o Go Into Programming
o Go Into Programming
o Go Into Programming
o Go Into Programming
o Go Into Programming
Turn off (dark display) by pressing ON/OFF
Continue holding BREW
BREW button. Display will read
BREW
BREW
BREW
correspond to the buttons (see illustration below).
1
2
3

PROGRAM MENUS

Model Select – Always perform this first. This feature re-sets all settings to the factory defaults.
Scroll through menu to Model Select. Choices are ALPHA-1, ALPHA-2, ALPHA-3/4/5, Airpot Brewer and Thermo-Alpha. Select only
Thermo-Alpha.
During actual brew
cycle a 2-minute drip
mode is added to the
brew time. The
programmed water level
compensates for back to back
brewing in Delta 3 to allow for an
increase of water volume.
Press
to Select. Press < or > to move to desired temperature and then
2-degree increments.
Energy Save Mode (Factory set to OFF)
Press
to Select, < or > ON, OFF or ON 140ºF ,
is OFF, unit does not have the energy saving mode.
In the ON 140ºF position, temperature goes down to 140ºF. if unit has not brewed in 4 hours. This feature will save energy by not heating the
tank during periods of non-operation.
Brew Count Odom.
Press
to display total brew cycles. Press ex or Reset
Pre-Infusion (Factory set to OFF)
Press
to Select. Current setting in seconds is displayed < to decrease or select > to increase (range from OFF to 10 through 60 sec-
onds),
to set.
If Pre-infusion is selected (ON), Cold Brew Lock is set to Delta 1 within 5ºF of set point and Cold Brew Lock is dissappears from the list
of program selections. When Pre-infusion is ON, Pulse Brew dissappears from the list of program selections.
.
Brew Count Total
Press
to Select, Shows total gallons and total brew cycles on the unit. Not resettable.
Cold Brew Lock . . . (Factory set to OFF)
Press
to select, < or > to select desired setting (CBL 5, 15 or OFF),
The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point. The first setting is
within 5 degrees of set point, next is within 15 degrees of set point, OFF is within 30 degrees of set point for the Ready to Brew message,
however it will brew at any temperature. This feature will operate after initialization to set temperature after the rear standby toggle switch is
reset to ON.
2
actory Pre-Set for Optimum P
actor
actor
y Pre-Set for Optimum P
y Pre-Set for Optimum Performance.
y Pre-Set for Optimum P
actor
y Pre-Set for Optimum P
. Press ON/OFF button and the screen will display
when temperature reaches the setpoint (200°F). Unit is now ready to brew.
ON/OFF
ON/OFF
ON/OFF button (yellow). Press and hold BREW
ON/OFF
ENTERING PROGRAM
, wait until
MODE
4
Brew Volume (Factory set to 60 oz.)
Selecting Brew by Volume or Brew by Time depends on whether you know your brew time before starting.
From Program Menus press > display will now show the next feature.
Brew by Volume: Press
to Select, Display will now show Push START To Begin... Press the BREW
button then hot water starts running, when desired volume is reached press BREW button again to stop the
flow. Now the volume has been set. Pressing > button will display the subsequent menu features.
Next item in the sequence is Brew by Time. Press
show the current time. By pressing < or > you can toggle back and forth from minutes to seconds to exit (ex).
Change the time or set and exit by pressing
Temperature (Factory set to 200°F)
to set. When in ON, unit will automatically shut off 4 hours from last brew. When feature
erformance.
erformance.
erformance.
erformance.
<D60GT>
CURTIS
BREW
BREW
BREW button (green) and then press and release ON/OFF
BREW
ENTER CODE
is displayed Enter the 4-digit access code, the digits 1-4
– – – –
The default code set at the factory is 1-2-3-4. Then
All programming selections are performed with the three center buttons.
The symbols below the buttons are:
Scroll LEFT
SELECTION or ENTER to save new parameter
Scroll RIGHT
Exit
Exit
Exit
Exit
Exit
Press
to Select to change the brew time. Display will now
.
to set. Temperature is programmable from 170ºF to 204ºF in
to set.
CURTIS
. After three seconds,
FILLING
CURTIS
HEATING
ON/OFF
ON/OFF
ON/OFF button (yellow).
ON/OFF
PROGRAM MENUS
<
SELECT
to select, exits program mode and returns unit to operation.
D60GT
is displayed.
will appear on the
will be displayed.
>