Summary of Contents for Trane 4YCY4060A

  • Page 1: Product Data

    22-1797-03 Product Data 4YCY4024A through 4YCY4060A Single Packaged Convertible Gas/Electric 14 SEER 2 - 5 Ton, 40 - 120 KBTU R-410A Pub. No. 22-1797-03 2008 Trane ©...
  • Page 2 Single Packaged Convertible Gas/Electric System Trane offers a complete family of packaged gas/electric heating and cooling sys- tems, designed to give you the unbeatable combination of energy efficiency and lower operating costs. In warm weather, the packaged gas/electric system functions as an all-electric, high efficiency air conditioner.
  • Page 3: Table Of Contents

    Contents Optional Equipment Listing General Data Performance Data Cooling Indoor Fan Typical Wiring Optional Equipment Dimensional Data Mechanical Specifications...
  • Page 4: Optional Equipment Listing

    Optional Equipment Listing OPTIONAL EQUIPMENT FOR PACKAGED UNITS (check mark [✓ ✓ ✓ ✓ ✓ ] indicates accessories included) Hinged Filter Access Door (4YCY4024-036) 8 ..............BAYACCDOR1A[ Hinged Filter Access Door (4YCY4042-060) 8 ..............BAYACCDOR2A[ Roof Curb Full Perimeter (4YCY4024-36A) 3 ..............BAYCURB050A[ ] Roof Curb Full Perimeter (4YCY4042-60A) 3 ..............
  • Page 5: General Data

    General Data MODEL 4YCY4024A1064A 4YCY4030A1075A 4YCY4036A1075A 4YCY4036A1096A RATED Volts/PH/Hz 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 23400 30000 36000 36000 Performance Cooling BTUHj 1210 1210 Indoor Airflow (CFM) 2.162 3.284 3.284 Power Input (KW) 11.6 / 14.0 12.0 / 14.0 11.6 / 14.2 11.6 / 14.2 EER/SEER(BTU/Watt-Hr.)n Sound Power Rating [dB(A)]8...
  • Page 6 General Data MODEL 4YCY4036A3075A 4YCY4036A3096A 4YCY4042A1096A RATED Volts/PH/Hz 208-230/3/60 208-230/3/60 208-230/1/60 Performance Cooling BTUHj 36000 36000 42000 Indoor Airflow (CFM) 1210 1210 1350 Power Input (KW) 3.284 3.284 EER/SEER(BTU/Watt-Hr.)n 11.6 / 14.2 11.6 / 14.2 12.0 / 14.25 Sound Power Rating [dB(A)]8 Performance Heatingk Input BTUH - 1st Stage (Natural Gas)p 56250...
  • Page 7 General Data MODEL 4YCY4048A1096A 4YCY4048A3096A 4YCY4048A1120A RATED Volts/PH/Hz 208-230/1/60 208-230/1/60 208-230/3/60 Performance Cooling BTUHj 48000 48000 48000 Indoor Airflow (CFM) 1605 1605 1605 Power Input (KW) 4.034 4.034 4.034 EER/SEER(BTU/Watt-Hr.)n 11.9 / 14.2 11.9 / 14.2 11.9 / 14.2 Sound Power Rating [dB(A)]8 Performance Heatingk Input BTUH - 1st Stage (Natural Gas)p 72000...
  • Page 8 General Data 4YCY4060A3120A MODEL 4YCY4048A3120A 4YCY4060A1120A 208-230/3/60 RATED Volts/PH/Hz 208-230/3/60 208-230/1/60 48000 58500 58500 Performance Cooling BTUHj 1605 1800 1800 Indoor Airflow (CFM) 4.034 5.478 5.478 Power Input (KW) 11.9 / 14.2 11.9 / 14.0 11.9 / 14.0 EER/SEER(BTU/Watt-Hr.)n Sound Power Rating [dB(A)]8 Performance Heatingk 90000 90000...
  • Page 9: Cooling

    Performance Data Cooling 4YCY4030A1 AT 1000 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES) SENS CAP AT ENTERING DB TEMP TOTAL USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW AIR FLOW CAPACITY TOTAL POWER 29.8 24.1 26.9 29.2 28.9 RATE, CFM...
  • Page 10 Performance Data Cooling 4YCY4042A1 AT 1400 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES) SENS CAP AT ENTERING DB TEMP TOTAL USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW AIR FLOW CAPACITY TOTAL POWER 40.3 34.1 38.4 40.3 40.3 RATE, CFM...
  • Page 11: Indoor Fan

    Indoor Blower Performance Indoor Fan Performance 4YCY4024A Horizontal Airflow 4YCY4024A-HOR External Static Pressure (in. wg) Motor Speed Watts 115 140 164 186 206 229 259 300 CFM 706 716 727 733 731 719 700 679 662 659 682 Watts 120 148 177 207 233 254 267 290 320 MED* 793 805 813 813 806 793 780 778 799 800 Watts...
  • Page 12: Indoor Blower Performance

    Indoor Blower Performance Indoor Fan Performance 4YCY4036A Horizontal Airflow 4YCY4036A-HOR External Static Pressure (in. wg) Motor Speed Watts CFM 1058 1062 1063 1063 1062 1060 1057 1053 1048 1042 1033 Watts MED* CFM 1179 1196 1204 1206 1205 1203 1199 1194 1185 1169 1144 Watts HIGH CFM 1390 1376 1370 1366 1361 1354 1349 1351 1369...
  • Page 13 MED* CFM 1582 1614 1624 1624 1621 1618 1618 1620 1618 1606 1574 Watts HIGH CFM 1816 1829 1836 1839 1840 1840 1844 1835 1830 1825 Indoor Fan Performance 4YCY4060A Horizontal Airflow 4YCY4060A-HOR External Static Pressure (in. wg) Motor Speed...
  • Page 14 8-ON 1200 1700 7-OFF 8-ON 1150 * can be 1 or 3 7-ON 8-ON 1250 * can be 1 or 3 4YCY4060A Nominal Airflow 4YCY4036A*096 Switch Settings Selection Low Stage High Stage Switch Settings Selection Nominal Airflow 7-OFF 8-OFF 1375...
  • Page 15: Typical Field Wiring

    Typical Field Wiring UNIT CONTROL BOX COMMON (GR) COMPRESSOR (WH) HEAT FIRST STAGE HEAT SECOND STAGE (WH) GROUND WIRE 1 PH POWER 3 PH POWER UNIT NOTE 1 COMMON (GR) COMPRESSOR (GR) HEAT FIRST STAGE (WH) (WH) HEAT SECOND STAGE (WH) (WH) C 757192i2...
  • Page 16: Typical Wiring

    Typical Wiring...
  • Page 17 Typical Wiring From Dwg. 21D757165 P02...
  • Page 18: Optional Equipment

    Optional Equipment BAYCURB050A Full Perimeter Roof Mounting Curb for *****018-036A 17 7/8 46 3/8 3 5/8 19 1/2 2 3/16 19 1/2 38 7/8 1 1/2 The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only.
  • Page 19 Optional Equipment BAYCURB051A Full Perimeter Roof Mounting Curb for *****042-060A 15 7/8 56 1/8 1 1/2 10 7/8 19 1/2 4 3/4 19 1/2 41 7/8 The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only.
  • Page 20 Optional Equipment BAYFLTR101, 201B, 1" - 2" Filter Rack (Mounts in Filter/Coil Section) Filter BAYACCDOR1A & BAYACCDOR2A Hinged Filter Access Door Replaces Filter/Coil Access Panel The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings.
  • Page 21 Optional Equipment BAYECON101,102A Down Discharge Economizer and Rain Hood (Mounts Over Horizontal Return Air Opening) HVAC Unit Economizer rain hood Economizer Unit ApplicationM odels 2/4YC,WC3018-036A Outside air BAYECON101A 4TC*3018-036A 20.125" dampers 4W/T/Y/DCY4024-060 Required filter 2/4YC,WC3042-060A Return air kit, order BAYECON102A 4TC*3042-060A 24.375"...
  • Page 22 Optional Equipment BAYOSAH001,002A, 25% Outside Air Damper (Replaces Filter/Coil Access Panel) The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the FULLY items depicted in the drawings.
  • Page 23: Dimensional Data

    Dimensional Data 4YCY4024A through 4YCY4036A (1 of 3)
  • Page 24 Dimensional Data 4YCY4024A through 4YCY4036A (2 of 3)
  • Page 25 Dimensional Data 4YCY4024A through 4YCY4036A (3 of 3)
  • Page 26 Dimensional Data 4YCY4042A through 4YCY4060A (1 of 3)
  • Page 27 Dimensional Data 4YCY4042A through 4YCY4060A (2 of 3)
  • Page 28 Dimensional Data 4YCY4042A through 4YCY4060A (3 of 3)
  • Page 29: Mechanical Specifications

    250 to 300 psig. All units have TXV to control refrigeration flow. Trane The manufacturer has a policy of continuous product and product data improvement and it reserves the right to 6200 Troup Highway Tyler, TX 75707-9010 change design and specifications without notice.